Eaton Moeller® series E58 Thru-beam photoelectric sensor, receiver, Sn=6m, 4L, 10-30VDC, light/dark, NPN, PNP, M18, insulated material 12102A6517
| Product Name |
Eaton Moeller® series E58 Thru-beam photoelectric sensor
|
| Catalog Number |
135575
|
| EAN |
4015081323685
|
| Product Length/Depth |
38.1 mm
|
| Product Height |
38.1 mm
|
| Product Width |
38.1 mm
|
| Product Weight |
0.23 kg
|
| Certifications |
CE
CSA File No.: 50513 CSA-C22.2 No. 14 UL File No.: E117028 CSA Class No.: 3211-07 UL UL Category Control No.: NRKH, NRKH7 UL 508 IEC/EN 60947-5-2 CSA |
| Model Code |
12102A6517
|
| Type |
Optical sensors
|
| Features |
Straight beam
|
| Device type |
Receiver
|
| Electric connection type |
Cable
|
| Enclosure material |
Plastic
|
| Enclosure type |
Cylinder, screw-thread
|
| Operating mode |
Switching principle: Adjustable bright/dark switching
|
| Explosion safety category for dust |
None
|
| Explosion safety category for gas |
None
|
| Functions |
Short-circuit protection
Protection against polarity reversal Thru-light beam Detector (for combination with source) |
| Voltage type |
DC
|
| Wire size |
0
|
| Connection type |
4-wire
2 m connection cable |
| Cable sheath material |
Polyurethane (PUR)
|
| Light type |
Polarity free red light
|
| Degree of protection |
IP67
NEMA 1 |
| Interface type |
Other
|
| LED indicator |
Status indication of Switching state: Red LED
|
| Switch function type |
Programmable/configurable
|
| Load current |
Max. 250 mA (Ie, NPN, 120 > 50°C)
Max. 100 mA (Ie, PNP) |
| Laser protection class |
None
|
| Operation agent-safety class |
Safety class 2
|
| Shock resistance |
100 g, Mechanical, Shock duration 3 ms
|
| Optical surface material |
Plastic
|
| Output current (mA) - max |
100 mA
|
| Rated control supply voltage (Us) at DC - max |
30 V
|
| Rated control supply voltage (Us) at DC - min |
10 V
|
| Rated switching distance (Sn) |
24000 mm
|
| Sensor length |
70 mm
|
| Switching distance - max |
24000 mm
|
| Voltage rating - max |
30 V
|
| Safety type (IEC 61496-1) |
1
|
| Switching frequency |
142 Hz
|
| Sensing mode |
Light-/dark switching
|
| Switching output type |
NPN
|
| Sensor material |
Insulated material
|
| Product category |
Comet Series
|
| Response time |
7 ms
|
| Ambient operating temperature - max |
70 °C
|
| Ambient operating temperature - min |
-20 °C
|
| Diameter sensor |
18 mm
|
| Number of contact energized outputs with signalling function |
0
|
| Number of outputs (protected contact energized) |
0
|
| Number of outputs (protected semiconductor) |
0
|
| Number of outputs (semiconductor with signaling function) |
0
|
| Operational current (Ib) in the switched state at 24 V DC |
30 A
|
| Adjustment type |
Manual adjustment
|