Eaton Moeller® series DILH Contactor, Ith =Ie: 850 A, 220 - 240 V 50/60 Hz, AC operation, Screw connection
| Product Name | 
                                                Eaton Moeller® series DILH contactor
                                             | 
| Catalog Number | 
                                                197909
                                             | 
| EAN | 
                                                4015081954285
                                             | 
| Product Length/Depth | 
                                                216 mm
                                             | 
| Product Height | 
                                                237 mm
                                             | 
| Product Width | 
                                                160 mm
                                             | 
| Product Weight | 
                                                8.85 kg
                                             | 
| Certifications | 
                                                CSA Class No.: 3211-04  VDE 0660 IEC/EN 60947-4-1 UL File No.: E29096 CE marking UL Category Control No.: NLDX UL 60947-4-1 UL/CSA CSA file No. 012528 North America (UL listed, CSA certified) EN 45545: Fire protection on railway vehicles IEC 61373: Vibration and shock, tested for category 1 class B | 
| Catalog Notes | 
 | 
| Model Code | 
                                                DILH600-S/22(220-240V50/60HZ)
                                             | 
| Accessories | 
                                                Fitting options auxiliary contacts: on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
                                             | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Fitted with: | 
                                                Suppressor circuit in actuating electronics
                                             | 
| Operating frequency | 
                                                1000 mechanical Operations/h (DC operated)  1000 mechanical Operations/h (AC operated) | 
| Pollution degree | 
                                                3
                                             | 
| Utilization category | 
                                                AC-1: Non-inductive or slightly inductive loads, resistance furnaces
                                             | 
| Climatic proofing | 
                                                Damp heat, cyclic, to IEC 60068-2-30  Damp heat, constant, to IEC 60068-2-78 | 
| Rated impulse withstand voltage (Uimp) | 
                                                12000 V
                                             | 
| Connection | 
                                                Screw terminals
                                             | 
| Ambient operating temperature - max | 
                                                70 °C
                                             | 
| Ambient operating temperature - min | 
                                                -40 °C
                                             | 
| Ambient storage temperature - max | 
                                                80 °C
                                             | 
| Ambient storage temperature - min | 
                                                -40 °C
                                             | 
| Conventional thermal current Ith (3-pole, enclosed) | 
                                                600 A
                                             | 
| Conventional thermal current Ith at 55°C (3-pole, open) | 
                                                725 A
                                             | 
| Conventional thermal current Ith of main contacts (1-pole, open) | 
                                                1738 A
                                             | 
| Equipment heat dissipation, current-dependent Pvid | 
                                                0 W
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Application | 
                                                Mains contactors for resistive loads from 1000 A
                                             | 
| Product category | 
                                                Contactors
                                             | 
| Electrical connection type of main circuit | 
                                                Rail connection
                                             | 
| Screwdriver size | 
                                                2, Terminal screw, Pozidriv screwdriver  0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver | 
| Voltage type | 
                                                AC
                                             | 
| Degree of protection | 
                                                IP00
                                             | 
| Number of auxiliary contacts (normally closed contacts) | 
                                                2
                                             | 
| Number of auxiliary contacts (normally open contacts) | 
                                                2
                                             | 
| Number of contacts (normally closed) as main contact | 
                                                0
                                             | 
| Number of main contacts (normally open contact) | 
                                                3
                                             | 
| Rated breaking capacity at 1000 V | 
                                                1575 A
                                             | 
| Rated breaking capacity at 220/230 V | 
                                                4800 A
                                             | 
| Rated breaking capacity at 380/400 V | 
                                                4800 A
                                             | 
| Rated breaking capacity at 500 V | 
                                                4800 A
                                             | 
| Rated breaking capacity at 660/690 V | 
                                                2000 A
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                                120 V
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                                110 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                                120 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                                110 V
                                             | 
| Overvoltage category | 
                                                III
                                             | 
| Behavior in marginal and transitional conditions | 
                                                Sealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged specifically  Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on properly Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor Sealing - Voltage drops (0.2 - 0.6 x Uc min ≤12 ms: Time is bridged specifically Sealing - Pick-up phase (0 - 0.7 x Uc min: Contactor does not switch on Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on | 
| Duty factor | 
                                                100 %
                                             | 
| Electromagnetic compatibility | 
                                                Designed for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.
                                             | 
| Lifespan, mechanical | 
                                                3,000,000 Operations (DC operated)  3,000,000 Operations (AC operated) | 
| Pick-up voltage | 
                                                0.85 - 1.1 V AC x Us
                                             | 
| Power consumption, pick-up, 50 Hz | 
                                                715 VA, Pull-in power, Coil in a cold state and 1.0 x Us  645 W, Pull-in power, Coil in a cold state and 1.0 x Us | 
| Safe isolation | 
                                                1000 V AC, Between coil and contacts, According to EN 61140
                                             | 
| Power consumption, pick-up, 60 Hz | 
                                                645 W, Pull-in power, Coil in a cold state and 1.0 x Us  715 VA, Pull-in power, Coil in a cold state and 1.0 x Us | 
| Screw size | 
                                                M3.5, Terminal screw  M10, Terminal screw | 
| Power consumption, sealing, 50 Hz | 
                                                3.3 W, Coil in a cold state and 1.0 x Us
                                             | 
| Power consumption, sealing, 60 Hz | 
                                                3.3 W, Coil in a cold state and 1.0 x Us
                                             | 
| Resistance | 
                                                500 mΩ (Admissible transitional contact resistance - of the external control circuit device when actuating A11)
                                             | 
| Switching capacity (auxiliary contacts, general use) | 
                                                10 A, 600 V AC, (UL/CSA)  1 A, 250 V DC, (UL/CSA) | 
| Switching capacity (auxiliary contacts, pilot duty) | 
                                                P300, DC operated (UL/CSA)  A600, AC operated (UL/CSA) | 
| Terminal capacity (flexible with ferrule) | 
                                                1 x (0.75 - 2.5) mm²  2 x (0.75 - 2.5) mm² | 
| Shock resistance | 
                                                10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms  8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms | 
| Terminal capacity (solid) | 
                                                2 x (0.75 - 2.5) mm²  1 x (0.75 - 2.5) mm² | 
| Terminal capacity (solid/stranded AWG) | 
                                                18 - 14
                                             | 
| Signal level | 
                                                5 V - 15 V, PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2), Magnet systems
                                             | 
| Terminal capacity (busbar) | 
                                                50 mm width, Main connection
                                             | 
| Terminal capacity (flexible with cable lug) | 
                                                50 - 240 mm²
                                             | 
| Switching capacity (main contacts, general use) | 
                                                700 A, Maximum motor rating (UL/CSA)
                                             | 
| Terminal capacity (stranded with cable lug) | 
                                                70 - 240 mm²
                                             | 
| Power consumption | 
                                                Control transformer with uk ≤ 7%
                                             | 
| Tightening torque | 
                                                1.2 Nm, Screw terminals  24 Nm, Main cable connection screw/bolt | 
| Width across flats | 
                                                16 mm
                                             | 
| Rated control supply voltage (Us) at DC - max | 
                                                0 V
                                             | 
| Rated control supply voltage (Us) at DC - min | 
                                                0 V
                                             | 
| Rated insulation voltage (Ui) | 
                                                1000 V
                                             | 
| Rated making capacity up to 440 V (cos phi to IEC/EN 60947) | 
                                                6000 A
                                             | 
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 
                                                0 A
                                             | 
| Rated operational current (Ie) at AC-4, 400 V | 
                                                0 A
                                             | 
| Rated operational current for specified heat dissipation (In) | 
                                                650 A
                                             | 
| Rated operational power at AC-3, 380/400 V, 50 Hz | 
                                                0 kW
                                             | 
| Rated operational power at AC-4, 380/400 V, 50 Hz | 
                                                0 kW
                                             | 
| Rated operational power (NEMA) | 
                                                0 kW
                                             | 
| Rated operational voltage (Ue) at AC - max | 
                                                1000 V
                                             | 
| Static heat dissipation, non-current-dependent Pvs | 
                                                3.3 W
                                             | 
| Stripping length (control circuit cable) | 
                                                10 mm
                                             | 
| Switching time (AC operated, make contacts, closing delay) - max | 
                                                60 ms
                                             | 
| Switching time (AC operated, make contacts, opening delay) - max | 
                                                50 ms
                                             | 
| Conventional thermal current Ith at 40°C (3-pole, open) | 
                                                850 A
                                             | 
| Conventional thermal current Ith at 50°C (3-pole, open) | 
                                                760 A
                                             | 
| Conventional thermal current Ith at 60°C (3-pole, open) | 
                                                695 A
                                             | 
| Altitude | 
                                                Max. 2000 m
                                             | 
| Operating voltage at AC, 50 Hz - min | 
                                                220 V
                                             | 
| Operating voltage at AC, 50 Hz - max | 
                                                240 V
                                             | 
| Operating voltage at AC, 60 Hz - min | 
                                                220 V
                                             | 
| Operating voltage at AC, 60 Hz - max | 
                                                240 V
                                             |