Eaton Moeller® series Rapid Link - Reversing starter, 6.6 A, Sensor input 2, Actuator output 1, 230/277 V AC, AS-Interface®, S-7.4 for 31 modules, HAN Q4/2, with manual override switch
Product Name |
Eaton Rapid Link Reversing starter
|
Catalog Number |
199105
|
EAN |
4015081971633
|
Product Length/Depth |
120 mm
|
Product Height |
270 mm
|
Product Width |
220 mm
|
Product Weight |
1.81 kg
|
Certifications |
UL approval
IEC/EN 60947-4-2 CCC RoHS UL 60947-4-2 CE UL 60947-4-2 |
Catalog Notes |
Assigned motor rating: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm at 50 Hz or 1800 min at 60 Hz
|
Model Code |
RAMO5-W212A31-412RS1
|
Type |
Reversing starter
|
Features |
Parameterization: drivesConnect
Parameterization: Keypad Diagnostics and reset on device and via AS-Interface Parameterization: drivesConnect mobile (App) Parameterization: Fieldbus |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Key switch position AUTO
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Key switch position HAND Manual override switch Key switch position OFF/RESET Thermistor monitoring PTC 1 Actuator output Thermo-click Electronic motor protection Short-circuit release |
Class |
CLASS 10 A
|
Lifespan, electrical |
10,000,000 Operations (at AC-3)
|
Climatic proofing |
In accordance with IEC/EN 50178
< 95 %, no condensation |
Rated impulse withstand voltage (Uimp) |
4000 V
|
Model |
Reversing starter
|
Altitude |
Max. 2000 m
Max. 1000 m Above 1000 m with 1 % performance reduction per 100 m |
Lifespan, mechanical |
10,000,000 Operations (at AC-3)
|
Mains switch-on frequency |
Maximum of one time every 60 seconds
|
Electrical connection type of main circuit |
Plug-in connection
|
Mains voltage tolerance |
380 - 480 V (-15 %/+10 %, at 50/60 Hz)
|
Voltage type |
DC
|
Mounting position |
Vertical
|
Rated conditional short-circuit current (Iq) |
10 kA
|
Overvoltage category |
III
|
Connection |
Connections pluggable in power section
|
Off-delay |
20 - 35 ms
|
Functions |
For actuation of motors with mechanical brake
External reset possible Temperature compensated overload protection |
On-delay |
20 - 35 ms
|
System configuration type |
AC voltage
Phase-earthed AC supply systems are not permitted. Center-point earthed star network (TN-S network) |
Braking current |
≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake
|
Electromagnetic compatibility |
Class A
|
Current limitation |
0.3 - 6.6 A, motor, main circuit
Adjustable, motor, main circuit |
Output frequency |
50/60 Hz
|
Braking voltage |
230/277 V AC -15 % / +10 %, Actuator for external motor brake
|
Overload cycle |
AC-53a
|
Overload release current setting - min |
0.3 A
|
Rated conditional short-circuit current (Iq), type 2, 230 V |
0 A
|
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V |
0 A
|
Rated conditional short-circuit current, type 1, 480 Y/277 V |
10000 A
|
Rated conditional short-circuit current, type 1, 600 Y/347 V |
0 A
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated frequency - max |
63 Hz
|
Rated frequency - min |
47 Hz
|
Rated operational current (Ie) at 150% overload |
6.6 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
6.6 A
|
Shock resistance |
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft
|
Interfaces |
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Specification: S-7.4 (AS-Interface®) Number of slave addresses: 31 (AS-Interface®) |
Protocol |
AS-Interface profile cable: S-7.4 for 31 modules
ASI |
Rated control voltage (Uc) |
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
230/277 V AC (external brake 50/60 Hz) |
Supply frequency |
50/60 Hz, fLN, Main circuit
|
Rated operational current (Ie) |
6.6 A
|
Rated operational power at 380/400 V, 50 Hz - max |
3 kW
|
Rated operational power at 380/400 V, 50 Hz - min |
0.09 kW
|
Rated operational voltage |
400 V AC, 3-phase
480 V AC, 3-phase |
Short-circuit protection (external output circuits) |
Type 1 coordination via the power bus' feeder unit, Main circuit
|
Vibration |
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 57 Hz, Amplitude transition frequency on acceleration Resistance: 6 Hz, Amplitude 0.15 mm Resistance: According to IEC/EN 60068-2-6 |
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-10 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
-40 °C
|
Assigned motor power at 460/480 V, 60 Hz, 3-phase |
3 HP
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
1
|
Number of command positions |
2
|
Number of pilot lights |
0
|
Overload release current setting - max |
6.6 A
|
Rated operational power at AC-3, 220/230 V, 50 Hz |
0 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
3 kW
|
Rated power at 460 V, 60 Hz, 3-phase |
2.238 kW
|
Rated power at 575 V, 60 Hz, 3-phase |
0 kW
|
Product category |
Motor starter
|
Cable length |
10 m, Radio interference level, maximum motor cable length
|
Coordination class (IEC 60947-4-3) |
Class 1
|
Degree of protection |
IP65
NEMA 12 |
Electrical connection type for auxiliary- and control-current circuit |
Plug-in connection
|
Input current |
6.6 A (at 150 % Overload)
|
Power consumption |
8 W
|