התמונה מייצגת
Download
Eaton 93E UPS, Tower Online UPS, 200 kVA, 3 phase in/3 phase out, Power factor 0,9, 93E-200kVA
| Product Name |
Eaton 93E UPS
|
| Catalog Number |
93E200K
|
| Product Length/Depth |
600 mm
|
| Product Height |
800 mm
|
| Product Width |
1880 mm
|
| Product Weight |
457 kg
|
| Certifications |
CB
|
| Audible alarms |
Yes
|
| Auto shutdown function |
Yes
|
| Internal battery included |
No
|
| Battery charger type |
ABM technology
|
| External battery connection |
Hardwired
|
| BTU rating |
11489
|
| Color |
Black
|
| Communication |
Relay-MS, Network-MS, Modbus Card-MS
|
| Construction type |
Free standing model
|
| Efficiency (eco-mode) |
98 %
|
| Improved efficiency mode |
High Efficiency
|
| Number of communication slots |
2
|
| Feed type |
AC
|
| Form factor |
Tower
|
| Hot-swappable power modules |
No
|
| Input connection |
Fixed connection
|
| Input current distortion |
5 %
|
| Input nominal voltage |
400V default (380/400/415V)
|
| Noise level (standard mode) |
<70 dBA at 1 meter
|
| Number of output connections fixed connection |
1
|
| Operating Temperature |
0°C - 40°C,Batteries recommended max. +25°C
|
| Output frequency |
50 Hz (50/60 Hz programmable)
|
| Output power factor |
0.9
|
| Output voltage regulation |
±1%
|
| Overall efficiency |
94 %
|
| Overload |
102–125% load 10 minutes, 126–150% load 1 minute, >151% load 500ms at 40oC
|
| Package contents |
|
| Parallelable |
Parallel for capacity and redundancy
|
| Number of parallel units |
4
|
| Phase (input) |
3
|
| Phase (output) |
3
|
| Potential free switch contact |
No
|
| Rack mounting kit included |
No
|
| Snmp |
No
|
| Software compatibility |
IPP, IPM
|
| Standard factory warranty |
1 year
|
| Start-on-battery |
No
|
| Storage temperature |
-15°C-55°C without batteries
|
| Switch configuration |
Input, output, bypass, MBS, battery
|
| Topology |
Online
|
| Type Of Interface |
Other
|
| Internal maintenance bypass |
No
|
| User Interface (Hmi) |
5''LCD
|
| kVA rating |
200 kVA
|
| Voltage |
400Y/230V
|
| Wattage |
180000 W
|
| Number Of Output Connections With Protective Contact (Schuko) |
0
|
| Application |
Data center/ facility/IT
|
| Output effective power |
180 kW
|
| Transition time for full load |
0 s
|
| Efficiency (improved efficiency mode) |
0.985 %
|
| Voltage distortion output (linear load) - max |
2 %
|
| Integrated functionality |
Network Mangement
|
| Input frequency - min |
50 Hz
|
| Input frequency - max |
60 Hz
|
| Input voltage - min |
380 V
|
| Input voltage - max |
415 V
|
| Output voltage - min |
380 V
|
| Output voltage - max |
415 V
|
| Secondary Frequency Min |
50 Hz
|
| Secondary Frequency Max |
60 Hz
|
| Output apparent power |
200000 VA
|
| Primary frequency - max |
60 Hz
|
| Primary frequency - min |
50 Hz
|
| Runtime at half load |
0 min
|
| Runtime at full load |
0 min
|
| Mounting Method |
Tower
|
| Degree of Protection |
IP20
|