Eaton Moeller® series LS Position switch, Rotary lever, Complete device, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C, with M12 connector, EN 50047 Form A
Product Name |
Eaton Moeller® series LS Position switch
|
Catalog Number |
178138
|
EAN |
4015081734610
|
Product Length/Depth |
33.5 mm
|
Product Height |
125 mm
|
Product Width |
31 mm
|
Product Weight |
0.074 kg
|
Certifications |
IEC/EN 60947
|
Type |
|
Features |
Positive opening
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Operating frequency |
6000 Operations/h
|
Pollution degree |
3
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Enclosure material |
Insulated material
|
Rated impulse withstand voltage (Uimp) |
2500 V AC
|
Enclosure color |
Yellow Cover
|
Actuator type |
Rotary lever
|
Actuating torque of rotary drives |
0.2 Nm
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.17 W
|
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally open contacts) |
1
|
Rated insulation voltage (Ui) |
250 V
|
Rated operational current for specified heat dissipation (In) |
6 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
Accessories |
M12 connector included.
|
Product category |
Rotary lever
|
Design |
EN 50047 Form A
|
Mounting position |
As required
|
Rated conditional short-circuit current (Iq) |
1 kA
|
Overvoltage category |
III
|
Control circuit reliability |
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA) |
Connection type |
Cage Clamp
|
Degree of protection |
IP66
|
Lifespan, mechanical |
8,000,000 Operations
|
Repetition accuracy |
0.15 mm (Contacts/switching capacity)
|
Shock resistance |
25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms
|
Supply frequency |
Max. 400 Hz, Contacts
|
Operating speed |
Max. 1.5 m/s (with DIN cam, mechanical actuation)
|
Rated operational current (Ie) |
3 A at 24 V
0.8 A at 110 V 0.3 A at 220 V 4 A at AC-15, 380 V 400 V 415 V 6 A at AC-15, 24 V 1 A at AC-15, 220 V 230 V 240 V 4 A at AC-15, 115 V |
Short-circuit protection rating |
Max. 4 A gG/gL, Fuse, Contacts
|
Terminal capacity (flexible with ferrule) |
1 x (0.5 - 1.5) mm²
|
Terminal capacity (solid) |
1 x (0.5 - 2.5) mm²
|