SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Network Card Options, LCD, USB, DB9, 8 Outlets
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART1500RM2U
|
| UPC |
037332119209
|
| Product Length/Depth |
23.5 in
|
| Product Height |
8.7 in
|
| Product Width |
20 in
|
| Product Weight |
46.5 lb
|
| Compliances |
RoHS
FCC Class B TAA Compliant |
| Certifications |
NOM
UL 1778 CSA certified |
| Topology |
Line-interactive
|
| Form factor |
Rackmount
|
| Rack size |
2U
|
| Package contents |
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
12A
|
| Battery replacement |
RBC93-2U
|
| Runtime at half load |
13 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
|
| Output Receptacles |
5-15R
|
| Product Features |
Individually Controllable Load Banks
|
| Product Highlights |
Interactive LCD allows real-time monitoring of voltage, battery status and other data
Protects equipment against blackouts, brownouts, transient surges and line noise Maintains continuous 120V nominal output during brownouts and overvoltages Optional WEBCARDLX network interface allows you 24/7 remote access from anywhere Keeps equipment running during outages to allow time for file saves and safe shutdown |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110 / 120V
|
| Network Management Cards |
WEBCARDLXE
RELAYIOCARD |
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.9
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
4.5 min. (1350W)
|
| Communication interface |
EPO (emergency power off)
DB9 Serial Slot for SNMP / Web interface USB (HID enabled) USB and DB9 serial cables included |
| Battery Access |
Front panel battery access door
|
| Dc Voltage |
36
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Input Circuit Breakers |
15A
|
| Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
|
| Load Management Receptacles |
Two switchable two-outlet 5-15R load banks
|
| High Voltage Transfer to Battery Power |
147
|
| Low Voltage Transfer to Battery Power |
83
|
| Undervoltage Correction |
Input voltages between 83 and 107 are boosted by 14%
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
|
| Switch configuration |
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
|
| AC suppression joule rating |
570
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
1.5
|
| Output Capacity (kW) |
1.35
|
| Output Capacity (VA) |
1500
|
| Operating Elevation |
|
| Primary UPS Depth (mm) |
342
|
| Primary UPS Height (mm) |
88
|
| Primary UPS Width (mm) |
439
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
|
| Audible Alarms |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| Output Voltage Regulation (Line Mode) |
-21%, +8%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12%
|
| Rechargeable Battery |
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
| Nominal Voltage Details |
120v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
12
|
| Minimum Required Rack Depth (cm) |
43.18
|
| Minimum Required Rack Depth (inches) |
17
|
| UPS Input Cord Length (m) |
3.1
|
| UPS Power Module Dimensions |
3.45 x 17.3 x 13.45
|
| Power Mode Transfer Time |
2-4 milliseconds
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
| Optional Accessories |
2 post rackmount (2POSTRMKITWM)
2-4 post front rail rackmount (UPSHDEARKIT) 4 post rackmount short-depth (4POSTRAILKITWM) Tower (2-9USTAND) Wallmount (2POSTRMKITWM) |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
Individually controllable load banks |
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Auto probe monitoring and reboot (requires WEBCARDLX) Remote management Hot swappable batteries Surge/noise protection |