Descargar documento () de 20
We make what matters work*

SMART750RM1U

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rack/Vertical, Network Management Card Options, USB, DB9 Serial

Especificaciones generales

Product Name
Eaton Tripp Lite series SmartPro UPS
Catalog Number
SMART750RM1U
UPC
037332118813
Product Length/Depth
16.75 in
Product Height
1.75 in
Product Width
17.5 in
Product Weight
30 lb
Compliances
RoHS
FCC Class A
TAA Compliant
Certifications
CSA certified
NOM
UL 1778

Especificaciones del producto

Topology
Line-interactive
Rack size
1U
VA rating
750 VA
Package contents
  • SMART750RM1U UPS System
  • Mounting hardware
  • USB, DB9 and EPO Cabling
  • Instruction manual
Input cord length
10 ft
Input nominal voltage
120 VAC
Nominal frequency
60 Hz
Input frequency range
60 Hz
Receptacle
5-15R
Output nominal voltage
110 / 120V
Electric current - max
7A
Battery replacement
RBC64-1U
Battery type
Valve Regulated Lead Acid (VRLA)
Runtime at half load
13 min
Noise level
45 dBA maximum, front side 1m
Relative humidity
0-95% non-condensing
Input Plug Type
NEMA 5-15P
Output Receptacles
5-15R
Product Features
Individually Controllable Load Banks
Product Highlights
120V output, Corrects brownouts and overvoltages from 83V to 147V
USB, RS232, EPO and slot for Network Management Card options
To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later
0.8 Power Factor, Front panel status LEDs
Mounting brackets support 2 and 4 post installation
120V NEMA 5-15P input, 6 NEMA 5-15R outlets
.75kVA / 750VA / 600W line interactive 1U rack/vertical UPS, Sine wave output
98% line-mode efficiency, 2 switched load banks
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
Nominal Output Voltage
110V
115V
120V
Network Management Cards
WEBCARDLXE
TLNETCARD
Network Management Cards Details
Network management card optional
Output power factor
0.8
Phase (input)
Single-phase
Runtime at full load
4.9 min. (600W)
Communication interface
Slot for SNMP / Web interface
USB
EPO (emergency power off)
DB9 Serial
USB and DB9 serial cables included
Battery Access
Front panel battery access door
Dc Voltage
24
Operating Temperature Range
32° to 104°F (0° to 40°C)
Communications Cable
USB and DB9 cabling included
Grounding Details
Back panel grounding lug
Input Circuit Breakers
15A
Optional Mounting Accessory Notes
Optional 4POSTRAILKITWM enables installation in 4-port short-depth racks from 14.5 to 23.5 inches (368 to 597mm); Optional 4POSTRAILKIT1U enables installation in 4-post full-depth racks from 20.5 to 36 inches (521 to 914mm)
Load Management Receptacles
Two switchable single-outlet 5-15R load banks
High Voltage Transfer to Battery Power
147
Low Voltage Transfer to Battery Power
83
Undervoltage Correction
Input voltages between 83 and 107 are boosted by 14%
Application
  • Large Network
  • High-End Desktop/Small Network
  • Retail/Point of Sale
  • Hospitality
Switch configuration
2 Switches control off/on power status and alarm-cancel/self-test operation
AC suppression joule rating
450
Housing material
Steel
Output AC waveform (AC mode)
Sine wave
Output AC waveform (battery mode)
Pure Sine wave
Output Capacity (kVA)
0.75
Primary UPS Depth (mm)
425
Primary UPS Height (mm)
44
Primary UPS Width (mm)
445
AC Suppression Response Time
Instantaneous
Alarm Interface
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarms
Audible alarm indicates power-failure, overload and low-battery conditions
Battery Start Capability
Cold-start operation supported
Cooling Method
Fan
Battery Replacement Description
Hot-swappable, user replaceable batteries
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Output Voltage Regulation (Line Mode)
-21%, +8%
Output Voltage Regulation(Battery Mode)
+/- 5%
Overvoltage Correction
Input voltages between 128 and 147 are reduced by 12%
Rechargeable Battery
Less than 4 hours from 10% to 90% (typical, full load discharge)
Recommended Electrical Service
15A 120V
Storage Temperature
5° to 122°F (-15° to 50°C)
Form factor
Rackmount
Wall-mount
Included Mounting Accessory Description
Included mounting brackets provide front-rail installation in 2 or 4 post racks; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U & 4POSTRAILKITWM
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions
Nominal Voltage Details
120v nominal output in battery mode
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Maximum Input Amps
7
Minimum Required Rack Depth (cm)
50.8
Minimum Required Rack Depth (inches)
20
UPS Power Module Dimensions
1.75 x 17.5 x 16.75
Power Mode Transfer Time
5 milliseconds AC to DC; 1 millisecond DC to AC
TAA Compliance
Yes
Connected Equipment Insurance

$250,000 Ultimate Lifetime Insurance
Optional Accessories
4 post rackmount full-depth (4POSTRAILKIT1U)
4 post rackmount short-depth (4POSTRAILKITWM)
Vertical Mount Enclosures (SRWF5U36, SRWF5U, SRWF10UMOD)
EMI AC Noise Suppression
EMI / RFI AC Noise Suppression
UPS Input Connection Type
5-15P
High Availability UPS Features
Hot swappable batteries
Remote management
Auto probe monitoring and reboot (requires WEBCARDLX)
Surge/noise protection
Automatic voltage regulation (AVR)
Nominal Input Voltage Supported
120 VAC

Exportar especificación del producto