100664
Model Kodu: Z-D02/R/3-54

Eaton xEffect SASY 60i Enclosures Switch- & Controlgear Enclosure. Bus-mounted fuse base, 63A, 400 V, D02/E18, 54mm

General specifications

Product Name
Eaton xEffect SASY 60i Enclosures Switch- & Controlgear Enclosure
Catalog Number
100664
EAN
4015081005659
Product Length/Depth
201 mm
Product Height
57 mm
Product Width
54 mm
Product Weight
0.205 kg
Compliances
RoHS conform
Certifications
IEC/EN 60269-1
VDE 0636 Part 301
Model Code
Z-D02/R/3-54

Additional information

Functions
Uninterrupted operation (Control mode)
Basic device
D busbar mounted fuse device
Special features
  • Including protective shroud without front and bottom plate
  • Delivery, empty, without screw cap, with marking plate
Used with
20 mm x 5/10 mm rail
Double T profile
25 mm x 5/10 mm rail
12 mm x 5/10 mm rail
30 mm x 5/10 mm rail
Gauge ring
185 mm system
60 mm system
Busbar fuse material

Delivery program

Amperage Rating
63 A
Number of poles
Three-pole
Type
  • 185 mm system
  • 60 mm system
  • Busbar fuse material
  • Gauge ring

Design verification as per IEC/EN 61439 - technical data

Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-25 °C
Heat dissipation per contact with fuse link at Ie
1.5 W
Permitted heat loss from fuse links - max
5.5 W

Technical Data - Electrical

Conventional thermal current Ith of auxiliary contacts (1-pole, open)
63 A
Current heat loss per contact at Ie
0.5 W
Frequency rating
40 Hz - 60 Hz
Frequency rating of contacts
40 Hz - 60 Hz
Overvoltage category
III
IV
Pollution degree
3
Rated conditional short-circuit current tested with links
50 kA
Rated impulse withstand voltage (Uimp)
6 kV
Rated operation current (Ie)
63 A
Rated operational voltage (Ue) - max
400 V
Voltage rating
400 V
Voltage rating at AC
  • 400 V AC
  • Contacts: 400 V AC

Technical Data - Mechanical

Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Construction size
D02
Degree of protection
IP20 enclosed
Distance between busbar centers
60 mm
Enclosure width
201 mm
Frame
E18, D02
Material
Plastic
Mounting method
Rail system
Mounting position
Vertical or horizontal
Mounting width
27 mm
54 mm
Terminal capacity (solid wire)
1.5 mm² - 35 mm² at box terminal
1.5 mm² - 35 mm²
Terminals
Lift terminals
Thread type
E18