StarLED 20m Viewing Distance, Maintained/ Non Maintained, IP42, 150 lm, Mains Lighting up to 100 lm, 1H Autonomy, Manual Test, 3 Adhesive Exit Legends (L,R,D)
| Product Name |
Eaton SafeLite emergency luminaire
|
| Catalog Number |
STARLED-013
|
| EAN |
3660191606428
|
| Product Length/Depth |
270 mm
|
| Product Height |
49 mm
|
| Product Width |
119 mm
|
| Product Weight |
0.32 kg
|
| Battery voltage |
3.6 V
|
| Battery number of cells |
3
|
| Battery quality |
NiCd
|
| Glow wire test |
850 °C
|
| Permissible ambient temperature - min |
5 °C
|
| Permissible ambient temperature - max |
40 °C
|
| Protection class |
II
|
| Degree of impact resistance (IK) |
IK 04
|
| Outdoor use compliance |
No
|
| Explosion protected |
No
|
| Degree of protection |
IP42
|
| Mode |
Maintained / Non-Maintained (M / NM)
|
| Lamp type |
LED not exchangeable
|
| With light source |
Yes
|
| Lamp holder |
None
|
| Type of indicator |
Only single-sided
|
| Monitoring equipment |
None
|
| Power supply system |
Peripheral (individual battery)
|
| Voltage type |
AC
|
| Apparent Power At Mains Operation |
3.2 VA
|
| Effective power at mains operation |
2.7 W
|
| Power factor |
0.84
|
| Wiring system |
Continuous circuit/emergency circuit
|
| With remote switch connection |
No
|
| Energy efficiency class |
A
|
| Conductor cross section |
2.5
|
| Connection type |
Plug-in connection
|
| Max. system power |
2.7 W
|
| Rated life time L70/B10 at 25 °C |
60000 hour
|
| Rated life time L70/B50 at 25 °C |
60000 hour
|
| Type of control gear |
Electronic transformer
|
| Type of wiring |
Suitable for through wiring
|
| Nominal voltage AC - max |
230 V
|
| Nominal voltage AC - min |
230 V
|
| Rated ambient temp acc. IEC62722-2-1 - Min |
5 °C
|
| Rated ambient temp acc. IEC62722-2-1 - Max |
40 °C
|
| Nominal operation time - min |
1 hour
|
| Nominal operation time - max |
1 hour
|
| Autonomy |
1 hour
|
| Energy efficiency class of the light source according to EU regulation 2019/2015 |
A
|
| Suitable for standby switching |
No
|
| Suitable for continuous circuit |
No
|
| RAL-Number (Similar) Housing |
9003
|
| Mounting Method |
Surface mounting/recessed mounting
|
| Material housing |
Plastic
|
| Color housing |
White
|
| Material cover |
Plastic, transparent
|
| Limited surface temperature |
No
|
| Labelling type |
Sticker
|
| Pictogram included |
True
|
| Built-in Length |
270 mm
|
| Built-in Width |
119 mm
|
| Built-in height/depth |
49 mm
|
| Number Of Poles (Numeric) |
2
|
| Impact strength |
IK04
|
| Kind of luminaire |
Safety and exit sign luminaire
|
| Rated Luminous Flux Acc. IEC 62722-2-1 |
150 lm
|
| Luminous flux at emergency operation |
50 lm
|
| Color temperature - max |
5053 K
|
| Color temperature - min |
5053 K
|
| Light distributor |
Reflector
|
| Energy efficiency class of the built-in lamp |
A++, A+, A (LED)
|
| Function |
Escape route lighting/signage
|
| Color of light |
White
|
| Color rendering index (CRI) |
70-79
|
| Luminaire With Limited Surface Temperature, Sign D |
No
|
| Number of lighting heads |
8
|
| Suitable for number of lamps |
1
|
| Viewing distance |
20 m
|
| Frequency |
50/60 Hz
|
| Main connection terminal |
0.5 - 2.5mm²
|
| Product branding |
Eaton
|
| Operating voltage - max |
240 V
|
| Operating voltage - min |
220 V
|
| Color temperature |
5053 K
|
| Power consumption mains operation - effective power (W) |
2.7 W
|
| Power consumption mains operation - apparent power (VA) |
3.2 VA
|
| Testing system |
No testing system
|
| With remote control |
No
|
| Constant light output (CLO) |
No
|
| Exchangeable control gear |
No
|
| Emergency function monitoring system |
Test button
|
| Emergency power supply system |
Peripheral (individual battery)
|
| Power consumption in emergency mode |
2.7 W
|
| With heating element for battery |
No
|