知識搜尋
下載文件 () / 20
已停產

Power Xpert 9395C UPS

The Eaton Power Xpert 9395C UPS has reached end-of-life status. Eaton will continue to provide services and replacement parts for the 9395C. If you're looking for a new UPS, the Eaton 9395P and 9395XC are the replacement UPS offerings.

Power rating
1000-1100 kVA
Voltage
480V
Form Factor
Tower

1MW monolithic UPS solution

Improved power per square foot without sacrificing performance

Customization and flexibility

• Offers a flexible system interface configuration
• Human Machine Interface (HMI) design allows customization display unique to your site layout
power-xpert-9395c-diagram.jpg

Ease of management

● Provides easier access to detailed status information
● Optimizes server virtualization through power management and connectivity software
● Increases uptime with 24x7 remote monitoring and reporting capabilities

Eaton lithium-ion batteries

The weight and dimensional benefits of lithium-ion battery cabinets create the optimal solution for your white or gray space.

Warranty and service plans

Eaton's UPS warranty and service options provide the system uptime, convenience and value that is right for you and your business.
規格

Power Xpert 9395C UPS technical specifications

UPS rating

1.0 power factor for 1000kVA/1000kW and 1100kVA/1100kW

0.91 power factor for 1100 kVA/1000kW only

kW/kVA 1,000 / 1,000
1,000 / 1,100
1,100 / 1,100
   
General characteristics  
Efficiency 

99% in Energy Saver System (ESS)

(up to 97% efficiency (480V) in double-conversion)

Parallel capability 

4 UPS units maximum for distributed bypass and

8 UPS units maximum with SBM

Audible noise  78dBA @ 1 meter
Altitude (max) 

1000 meters at 40°C (104°F) for 1000/1000

1000 meters at 40°C (104°F) for 1000/1100

1000 meters at 35°C (95°F) for 1100/1100

Control panel (LCD) Color touchscreen interface
Battery startup Standard
Frequency conversion Standard
Multi-language Standard
Building alarm inputs 5 (galvanic isolated)
   
Input characteristics  
Voltage 480V 3Wire
Voltage range +10% / -15%
Frequency range  45-65 Hz
Power factor  0.99 (minimum)
Input current distortion  <3% (no input filter required)
Soft start capability Yes
   
Output characteristics  
Voltage  480V 3Wire
Regulation  ±1%
Inverter  PWM with IGBT switching
Voltage THD <1% (100% linear load); <5% (non-linear load)
Load power factor range  Up to a 0.7 power factor lagging to 0.9 power factor leading without derating
Overload 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds
   
Battery  
Battery types  VRLA, AGM, wet cell, lithium-ion
Battery voltage  480V
Temperature compensation  Optional
Charging method  ABM technology or float, selectable
   
Dimensions and weights  
1000 kW/1000 kVA 147”w x 34.3”d x 77.3”h (5295 lb/2402 Kg)
1000 kW/1100 kVA 147”w x 34.3”d x 77.3”h (5295 lb/2402 Kg)
1100 kW/1100 kVA 147”w x 34.3”d x 77.3”h (5295 lb/2402 Kg)
   
Options
  • External maintenance bypass
  • PDU, RPP and STS
  • Maintenance bypass module, matching cabinet, 2/3/4 breaker
  • DC disconnects
  • 100 kAIC input breakers
   
Communication cards

Four communication bays standard. The following connectivity options can be installed at any time:

 

Remote inputs/outputs: Five building alarm inputs and one summary alarm contact (5A @ 120V) standard

Remote monitor panel: Eight backlit status indicator lamps plus an audible horn

   
Software compatibility

Eaton Intelligence Platform:

  • Automate: Make tasks simpler via advanced alerts and automated resolution
  • Monitor: Make data actionable through faster, scalable interpretation and analysis
  • Visualize: See beyond power consumption through 3D infrastructure visualizations
  • Predict: foresee power component failure with cloud-based analytics
Note: Due to continuing improvements, specifications are subject to change without notice. Please refer to Eaton Power Xpert 9395 technical documents for specific configuration guidelines and features.

Power Xpert 9395C UPS efficiency graphs

下載連結
X
Download Close