TAA SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, 3U, 120/230V input, Network Card Options, USB, DB9
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SM2200RMDVTAA
|
| UPC |
037332156310
|
| Product Length/Depth |
30 in
|
| Product Height |
12 in
|
| Product Width |
30 in
|
| Product Weight |
104.25 lb
|
| Compliances |
RoHS
FCC Class A TAA Compliant |
| Certifications |
UL 1778
NOM CSA certified |
| Topology |
Line-interactive
|
| Rack size |
3U
|
| VA rating |
2200 VA
|
| Package contents |
|
| Input nominal voltage |
120 VAC/230 VAC
|
| Nominal frequency |
50/60 Hz
|
| Input frequency range |
50/60 Hz
|
| Receptacle |
|
| Output nominal voltage |
120V
|
| Electric current - max |
16A (120V), 10A (230V)
|
| Battery replacement |
RBC49-DV (quantity 2 required)
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
30 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Input Plug Type |
C20
|
| Output Receptacles |
5-15R
5-15/20R |
| Product Features |
Individually Controllable Load Banks
Expandable Runtime |
| Product Highlights |
2200VA / 2.2kVA / 1920W line interactive 3U rack/tower UPS; 0.9 power factor
95% line-mode efficiency, 2 switched load banks C20 inlet and 4 international input line cords, 4 5-15R and 4 5-15/20R outlets Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases USB port, RS232, EPO and optional network management card slot; Detailed status LEDs To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later Maintains 120V output with 120V or 230V input, Sine wave output |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
120V
|
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.87
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
12 min. (1920W)
|
| Communication interface |
USB (HID enabled)
DB9 Serial EPO (emergency power off) Slot for SNMP / Web interface USB and DB9 serial cables included |
| Battery Access |
Front panel battery access door
|
| Typical Battery Runtime |
Expandable Runtime
|
| Dc Voltage |
48
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Input Circuit Breakers |
20A
|
| Load Management Receptacles |
Two switchable single-outlet 5-15R load banks
|
| High Voltage Transfer to Battery Power |
148 (120V), 286 (230V)
|
| Low Voltage Transfer to Battery Power |
89 (120V), 170 (230V)
|
| Undervoltage Correction |
Voltage boost of 12% applies when input voltage is between 96 and 108 (120V)
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
Large Network
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
|
| AC suppression joule rating |
340
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
2.2
|
| Primary UPS Depth (mm) |
641
|
| Primary UPS Height (mm) |
133
|
| Primary UPS Width (mm) |
445
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
| Frequency Rating Details |
Automatic frequency selection
|
| Minimum Required Rack Depth With External Battery Pack |
32.25
|
| Minimum Required Rack Depth Without External Battery Pack |
30.25
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Voltage reduction of 12% applies when input is between 127 and 148 (120V)
|
| Rechargeable Battery |
Less than 4.5 hours from 10% to 90% (internal batteries)
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Included Mounting Accessory Description |
Complete installation accessories available for 2 post, 4 post and tower installation
|
| Input Connection Description |
C20 inlet and 5 compatible plugsets (5-20P, Schuko CEE7, EU1-16P, British BS1363, Italian CEI 23-16)
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains 120v line power output with input range of 89 to 148 or 170 to 286
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
16
|
| Minimum Required Rack Depth (cm) |
73.66
|
| Minimum Required Rack Depth (inches) |
29
|
| UPS Input Cord Length (m) |
1.8
|
| UPS Power Module Dimensions |
5.25 x 17.5 x 25.25
|
| Power Mode Transfer Time |
2-4 milliseconds
|
| TAA Compliance |
Yes
|
| Optional Accessories |
4 post rackmount full-depth (4POSTRAILKIT)
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
C20 inlet
|
| External Battery Pack Compatibility |
BP48V24-2U (limit 1)
BP48V60RT-3U (multi-pack compatible) BP48V27-2US (multi-pack compatible) |
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
Individually controllable load banks |
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Hot swappable batteries Auto probe monitoring and reboot (requires WEBCARDLX) Remote management Surge/noise protection |
| Nominal Input Voltage Supported |
120 VAC/230 VAC
|