Tripp Lite series SmartPro 3000VA 3000W 120V Line-Interactive Sine Wave UPS - 7 Outlets, Network Card Included, LCD, USB, DB9, 2U Rack/Tower
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART3000RM2UN
|
| UPC |
037332177902
|
| Product Length/Depth |
23.7 in
|
| Product Height |
3.4 in
|
| Product Width |
17.2 in
|
| Product Weight |
74.516 lb
|
| Compliances |
RoHS
FCC Class A |
| Certifications |
CSA certified
UL 1778 NOM |
| Topology |
Line-interactive
|
| Rack size |
2U
|
| Color |
Black
|
| VA rating |
3000 VA
|
| Wattage |
3000 W
|
| Rack mounting kit |
Yes
|
| Package contents |
|
| Input connection |
L5-30P
|
| Input cord length |
10 ft
|
| Nominal frequency |
50/60 Hz
|
| Input frequency range |
50/60 Hz
|
| Input power factor |
1
|
| Receptacle |
|
| Number of Outputs 5-20R |
6
|
| Number of Outputs L5-30R |
1
|
| Output waveform |
Sine wave
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
24A (120V)
|
| Runtime graph |
|
| Battery replacement |
Pre-May 2023: RBC94-2U post-May 2023: 744-A3122
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Extended battery capability |
|
| Runtime at half load |
9 min
|
| Expansion slots |
One slot
|
| Ethernet interface |
Yes
|
| User interface |
LCD display
|
| Noise level |
50 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
|
| Input Plug Type |
NEMA L5-30P
|
| Output Receptacles |
L5-30R
5-15/20R |
| Product Features |
Individually Controllable Load Banks
Emergency Power Off (EPO)/Remote On-Off (ROO) |
| Product Highlights |
2-line front-panel LCD with 10 selectable screens reports detailed UPS and site power info
Unity power factor ensures maximum power possible at each power rating Keeps equipment running during outages to allow time for file saves and safe shutdown $250,000 Ultimate Lifetime Insurance (U.S., Canada and Puerto Rico only) Included WEBCARDLXE network interface allows 24/7 remote access and control 2 year warranty, 3 year with registration. (Worldwide) Note: Registration is required for 3 year warranty. Protects equipment against blackouts, brownouts, transient surges and line noise |
| PowerAlert Software |
For local monitoring via the UPS’s built-in Serial or USB communication ports, download PowerAlert Home software at https://www.tripplite.com/poweralert. LX Platform Interface: PowerAlert Device Manager 20 (PADM20)
|
| SNMP Compatibility |
SNMP V1, V2c, V3
|
| Nominal Output Voltage |
110V
115V 120V |
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card included
|
| Output power factor |
1
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
3 min. (3000W)
|
| Communication interface |
DB9 Serial
USB-A Slot for SNMP / Web interface USB (HID enabled) EPO (emergency power off) Pre-installed network card Micro-USB RJ45 network Micro-USB, USB, and DB9 cabling included |
| Battery Access |
Front panel battery access door
|
| EPO Port |
RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems
|
| Dc Voltage |
72
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
Micro-USB, USB, and DB9 cabling included
|
| Grounding Details |
Rear panel grounding lug
|
| Optional Mounting Accessory Notes |
Optional 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm)
|
| Output Circuit Breakers |
Three 20A output breakers protect 2x 5-20R outlets each
|
| Load Management Receptacles |
Two switchable two-outlet load banks
|
| High Voltage Transfer to Battery Power |
151
|
| Low Voltage Transfer to Battery Power |
80
|
| Undervoltage Correction |
Boost incoming voltages between 81-102V by 15% (Normal Mode); 71-92V by 15% (Extended Mode)
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
|
| Switch configuration |
5 pushbutton switches control OFF / ON power status, ENTER, UP, and DOWN selection and ESC control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
|
| AC suppression joule rating |
380
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Pure Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
3
|
| Operating Elevation |
|
| Primary UPS Depth (mm) |
602
|
| Primary UPS Height (mm) |
86
|
| Primary UPS Width (mm) |
437
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding the previous alarm silencing
|
| Audible Alarms |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable 72VDC internal battery cartridge
|
| LED Indicators |
Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LXE Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
|
| Output Voltage Regulation (Line Mode) |
120V (-13%, +15%)
|
| Output Voltage Regulation(Battery Mode) |
-10%, +6%
|
| Overvoltage Correction |
Reduces incoming voltage between 132-151V by 13% (Normal Mode); 138-152V (Extended mode)
|
| Rechargeable Battery |
Less than 5 hours from 10 to 90% (typical, full load discharge)
|
| Recommended Electrical Service |
30A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Form factor |
Rackmount
Wall-mount Tower |
| Included Mounting Accessory Description |
Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation.
|
| Input Nominal Voltage Description |
80V-151V; adjustable to 70-153V
|
| Network Monitoring Port |
RJ45 Network port, Micro-USB Configuration/Console port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
|
| Network Monitoring Port Description |
Includes pre-installed WEBCARDLXE Network Management Card interface. Not compatible with WEBCARDLX.
|
| Nominal Voltage Details |
120v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 150V (Normal mode) adjustable to 70-153V (Extended mode)
|
| Maximum Input Amps |
24
|
| Minimum Required Rack Depth (cm) |
69.85
|
| Minimum Required Rack Depth (inches) |
27.5
|
| UPS Input Cord Length (m) |
3.1
|
| UPS Power Module Dimensions |
3.4 x 17.2 x 23.7
|
| Power Mode Transfer Time |
1-4ms for normal mode, >5ms for sensitive mode
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance |
| Optional Accessories |
4 post rackmount short-depth (4POSTRAILKITWM)
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
L5-30P
|
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
Individually controllable load banks |
| Input Nominal Voltage |
120 VAC
|
| Network Compatibility |
10 Mbps
100 Mbps (Fast Ethernet) |
| High Availability UPS Features |
Surge/noise protection
Auto probe monitoring and reboot (included) Automatic voltage regulation (AVR) Hot swappable batteries Remote management Sine wave output |
| Nominal Input Voltage Supported |
120 VAC
|