Eaton Moeller® series EASY I/O expansion, For use with easyE4, 12/24 V DC, 24 V AC, Inputs expansion (number) digital: 8, screw terminal
| Product Name |
Eaton Moeller® series EASY I/O expansion
|
| Catalog Number |
197218
|
| EAN |
4015080892793
|
| Product Length/Depth |
58 mm
|
| Product Height |
90 mm
|
| Product Width |
72 mm
|
| Product Weight |
0.25 kg
|
| Certifications |
UL File No.: E205091
CE UL hazardous location class I UL hazardous location group B (hydrogen) UL hazardous location division 2 UL hazardous location group D (propane) UL hazardous location group A (acetylene) UL hazardous location group C (ethylene) cULus Ordinary Location DNV TAA00002HT cULus Hazard Location UL File No.: E523283 EN 61131-2 IEC 61131-2 EN IEC 61000-6-3 IEC 61000-6-3 EN IEC 61010-2-201 IEC 61010-2-201 UL 61010-1 UL 61010-2-201 CSA C22.2 No. 61010-1 CSA C22.2 No. 61010-2-201 UL 121201 CSA C22.2 No. 213 |
| Catalog Notes |
fitted with two controlled relays
|
| Model Code |
EASY-E4-UC-16RE1
|
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Mounting position |
Vertical
Horizontal |
| Shock resistance |
15 g, Mechanical, acc. to IEC/EN61131-2, Half-sinusoidal shock 11 ms, 18 Impacts
|
| Vibration resistance |
8.4 - 150 Hz, 1 g constant acceleration
5 - 8.4 Hz, 3.5 mm constant amplitude According to IEC/EN 61131-2 |
| Cable length |
Digital inputs (DC): ≤ 100 m (unshielded)
Digital inputs (AC): ≤ 40 m (unshielded) |
| Air pressure |
795 - 1080 hPa (operation)
|
| Ambient operating temperature - max |
55 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Environmental conditions |
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Condensation: prevent with appropriate measures |
| Relative humidity |
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)
|
| Connection type |
Screw terminal
|
| LED indicator |
Status indication of Power/RUN
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Equipment heat dissipation, current-dependent Pvid |
2 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Static heat dissipation, non-current-dependent Pvs |
3 W
|
| Power consumption |
3 W
|
| Power loss |
10 VA
|
| Rated breaking capacity |
300000 Operations at AC-15, 250 V AC, 3 A (600 Ops./h)
200000 Operations at DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 Ops./h) |
| Rated operational voltage |
Power supply: 24 V DC (-15 %/+ 20 %)
Power supply: 24 V AC (-15 %/+ 10 %) Power supply: 12 V DC (-15 %/+ 20 %) Relay outputs: max. 300 V AC/DC Inputs: shall be identical to the power supply voltage |
| Supply frequency |
50/60 Hz (± 5%)
|
| Supply voltage at AC, 50 Hz - max |
26.4 VAC
|
| Supply voltage at AC, 50 Hz - min |
20.4 VAC
|
| Supply voltage at DC - max |
28.8 VDC
|
| Supply voltage at DC - min |
10.2 VDC
|
| Uninterrupted current |
1 A DC, at R 300 (UL/CSA)
10 A AC, at 240 V AC (UL/CSA) 8 A DC, at 24 V DC (UL/CSA) 5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA) |
| Air discharge |
8 kV
|
| Burst impulse |
2 kV, I/O port
2 kV, Power supply port According to IEC/EN 61131-2 |
| Contact discharge |
6 kV
|
| Electromagnetic fields |
10 V/m at 0.08 - 1.0 GHz (according to IEC/EN 61131-2)
3 V/m at 1.0 - 6 GHz (according to IEC/EN 61131-2) |
| Immunity to line-conducted interference |
10 V (according to IEC/EN 61131-2)
|
| Radio interference class |
Class B (EN 61000-6-3)
|
| Surge rating |
1 kV, Line-to-Line, Power supply port
2 kV, Line-to-Earth, Power supply port According to IEC/EN 61131-2 |
| Voltage dips |
1 ms 12 V DC
10 ms at 24 V DC 20 ms at 24 V AC |
| Features |
Expansion device
Expandable |
| Fitted with: |
Relay output
|
| Indication |
Software used as status indication of digital I/Os
|
| Degree of protection |
IP20
|
| Duty factor |
100 %
|
| Input frequency |
50/60 Hz (Digital inputs at AC)
|
| Insulation resistance |
According to EN IEC 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-227
|
| Lifespan, electrical |
25,000 Operations (Filament bulb load at 500 W, 115/120 V AC)
25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC) 25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device) 25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated) 25,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated) |
| Lifespan, mechanical |
10,000,000 Operations
|
| Mounting method |
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Wall mounting/direct mounting Screw fixing using fixing brackets ZB4-101-GF1 (accessories) Front build in possible Rail mounting possible |
| Overvoltage category |
Power supply + Inputs + Right extension interface: II
Relay outputs: III Left extension interface: III |
| Pollution degree |
2
|
| Product category |
Control relays easyE4
|
| Protection |
B16 circuit breaker or 8 A (T) fuse, Protection of an Output relay
|
| Rated impulse withstand voltage (Uimp) |
Relay outputs: 6 kV (contact-coil)
|
| Residual ripple |
Power supply: ≤ 5 %
|
| Software |
EASYSOFT-SWLIC/easySoft
|
| Switching frequency |
10 Hz, Relay outputs
0.5 Hz, Inductive load, Relay outputs 2 Hz, Resistive load/lamp load, Relay outputs |
| Type |
easyE4 extension
|
| Used with |
easyE4
|
| Utilization category |
B 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes AC
R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC |
| Voltage type |
AC/DC
|
| Delay time |
Digital inputs (12 V DC): 0.2 ms typ., from 0 to 1
Digital inputs (12 V DC): 0.15 ms typ., from 1 to 0 Digital inputs (24 V DC): 0.1 ms typ., from 0 to 1 Digital inputs (24 V DC): 0.2 ms typ., from 1 to 0 Digital inputs (24 V AC 50 Hz): 25 ms typ., from 0 to 1 Digital inputs (24 V AC 50 Hz): 25 ms typ., from 1 to 0 Digital inputs (24 V AC 60 Hz): 21 ms typ., from 0 to 1 Digital inputs (24 V AC 60 Hz): 21 ms typ., from 1 to 0 |
| Input current |
3.3 mA (I1 - I8, at 24 V DC,at signal 1)
1.75 mA (I1 - I8, at 12 V DC,at signal 1) 3.5 mA (I1 - I8, at 24 V AC,at signal 1) |
| Input voltage |
Condition 0: ≤ 5 V DC (Digital inputs, 12 V DC)
Condition 0: ≤ 5 V DC (Digital inputs, 24 V DC) Condition 1: ≥ 15 V DC (Digital inputs, 24 V DC) Condition 1: ≥ 8 V DC (Digital inputs, 12 V DC) Condition 0: ≤ 5 V AC (Digital inputs, 24 V AC) Condition 1: ≥ 15 V AC (Digital inputs, 24 V AC) |
| Making/breaking capacity |
3600/360 VA (AC, at B 300)
28/28 VA (DC, at R 300) |
| Number of inputs (analog) |
0
|
| Number of inputs (digital) |
8
|
| Number of outputs (analog) |
0
|
| Number of outputs (digital) |
8
|
| Output |
8 Relay Outputs
min. recommended load: 12 V AC/DC > 500 mA |
| Parallel switching |
Not permitted
|
| Explosion safety category for dust |
None
|
| Explosion safety category for gas |
None
|
| Potential isolation |
Power supply + Inputs + right Extension interface against Outputs: yes
POW+Inputs+right Extension interface vs. left Extension interface: yes Outputs against left Extension interface: yes Outputs against each other: yes |
| Protection against polarity reversal |
Yes
|
| Safe isolation |
Relay outputs: 300 V AC, Between two contacts
Relay outputs: 300 V AC, Between coil and contact |
| Short-circuit protection |
≥ 1A (T), Fuse, Power supply
|
| Screwdriver size |
3.5 x 0.6 mm, Terminal screw
|
| Terminal capacity |
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm², flexible with ferrule 0.2 - 2.5 mm², flexible without ferrule |
| Tightening torque |
0.6 Nm, Screw terminals
|