Bilgi Arama
Belgeyi İndir () / 20
Zor İşler Bizimle Kolay

197218
EASY-E4-UC-16RE1

Eaton Moeller® series EASY I/O expansion, For use with easyE4, 12/24 V DC, 24 V AC, Inputs expansion (number) digital: 8, screw terminal

Genel Teknik Özellikler

Product Name
Eaton Moeller® series EASY I/O expansion
Catalog Number
197218
EAN
4015080892793
Product Length/Depth
58 mm
Product Height
90 mm
Product Width
72 mm
Product Weight
0.25 kg
Certifications
UL File No.: E205091
CE
UL hazardous location class I
UL hazardous location group B (hydrogen)
UL hazardous location division 2
UL hazardous location group D (propane)
UL hazardous location group A (acetylene)
UL hazardous location group C (ethylene)
cULus Ordinary Location
DNV
TAA00002HT
cULus Hazard Location
UL File No.: E523283
EN 61131-2
IEC 61131-2
EN IEC 61000-6-3
IEC 61000-6-3
EN IEC 61010-2-201
IEC 61010-2-201
UL 61010-1
UL 61010-2-201
CSA C22.2 No. 61010-1
CSA C22.2 No. 61010-2-201
UL 121201
CSA C22.2 No. 213
Catalog Notes
fitted with two controlled relays
Model Code
EASY-E4-UC-16RE1

Mekanik Ortam Koşulları

Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
Vertical
Horizontal
Shock resistance
15 g, Mechanical, acc. to IEC/EN61131-2, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance
8.4 - 150 Hz, 1 g constant acceleration
5 - 8.4 Hz, 3.5 mm constant amplitude
According to IEC/EN 61131-2

Kablo

Cable length
Digital inputs (DC): ≤ 100 m (unshielded)
Digital inputs (AC): ≤ 40 m (unshielded)

İklime bağlı ortam koşulları

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - max
55 °C
Ambient storage temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - min
-40 °C
Environmental conditions
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Condensation: prevent with appropriate measures
Relative humidity
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)

Haberleşme

Connection type
Screw terminal
LED indicator
Status indication of Power/RUN

Tasarım Doğrulaması

10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid
2 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Static heat dissipation, non-current-dependent Pvs
3 W

Elektrik Değeri

Power consumption
3 W
Power loss
10 VA
Rated breaking capacity
300000 Operations at AC-15, 250 V AC, 3 A (600 Ops./h)
200000 Operations at DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 Ops./h)
Rated operational voltage
Power supply: 24 V DC (-15 %/+ 20 %)
Power supply: 24 V AC (-15 %/+ 10 %)
Power supply: 12 V DC (-15 %/+ 20 %)
Relay outputs: max. 300 V AC/DC
Inputs: shall be identical to the power supply voltage
Supply frequency
50/60 Hz (± 5%)
Supply voltage at AC, 50 Hz - max
26.4 VAC
Supply voltage at AC, 50 Hz - min
20.4 VAC
Supply voltage at DC - max
28.8 VDC
Supply voltage at DC - min
10.2 VDC
Uninterrupted current
1 A DC, at R 300 (UL/CSA)
10 A AC, at 240 V AC (UL/CSA)
8 A DC, at 24 V DC (UL/CSA)
5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA)

Elektromanyetik Uyumluluk

Air discharge
8 kV
Burst impulse
2 kV, I/O port
2 kV, Power supply port
According to IEC/EN 61131-2
Contact discharge
6 kV
Electromagnetic fields
10 V/m at 0.08 - 1.0 GHz (according to IEC/EN 61131-2)
3 V/m at 1.0 - 6 GHz (according to IEC/EN 61131-2)
Immunity to line-conducted interference
10 V (according to IEC/EN 61131-2)
Radio interference class
Class B (EN 61000-6-3)
Surge rating
1 kV, Line-to-Line, Power supply port
2 kV, Line-to-Earth, Power supply port
According to IEC/EN 61131-2
Voltage dips
1 ms 12 V DC
10 ms at 24 V DC
20 ms at 24 V AC

Features & functions

Features
Expansion device
Expandable
Fitted with:
Relay output
Indication
Software used as status indication of digital I/Os

Genel Bilgiler

Degree of protection
IP20
Duty factor
100 %
Input frequency
50/60 Hz (Digital inputs at AC)
Insulation resistance
According to EN IEC 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-227
Lifespan, electrical
25,000 Operations (Filament bulb load at 500 W, 115/120 V AC)
25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)
25,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated)
Lifespan, mechanical
10,000,000 Operations
Mounting method
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Wall mounting/direct mounting
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Front build in possible
Rail mounting possible
Overvoltage category
Power supply + Inputs + Right extension interface: II
Relay outputs: III
Left extension interface: III
Pollution degree
2
Product category
Control relays easyE4
Protection
B16 circuit breaker or 8 A (T) fuse, Protection of an Output relay
Rated impulse withstand voltage (Uimp)
Relay outputs: 6 kV (contact-coil)
Residual ripple
Power supply: ≤ 5 %
Software
EASYSOFT-SWLIC/easySoft
Switching frequency
10 Hz, Relay outputs
0.5 Hz, Inductive load, Relay outputs
2 Hz, Resistive load/lamp load, Relay outputs
Type
easyE4 extension
Used with
easyE4
Utilization category
B 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes AC
R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC
Voltage type
AC/DC

Giriş/Çıkış

Delay time
Digital inputs (12 V DC): 0.2 ms typ., from 0 to 1
Digital inputs (12 V DC): 0.15 ms typ., from 1 to 0
Digital inputs (24 V DC): 0.1 ms typ., from 0 to 1
Digital inputs (24 V DC): 0.2 ms typ., from 1 to 0
Digital inputs (24 V AC 50 Hz): 25 ms typ., from 0 to 1
Digital inputs (24 V AC 50 Hz): 25 ms typ., from 1 to 0
Digital inputs (24 V AC 60 Hz): 21 ms typ., from 0 to 1
Digital inputs (24 V AC 60 Hz): 21 ms typ., from 1 to 0
Input current
3.3 mA (I1 - I8, at 24 V DC,at signal 1)
1.75 mA (I1 - I8, at 12 V DC,at signal 1)
3.5 mA (I1 - I8, at 24 V AC,at signal 1)
Input voltage
Condition 0: ≤ 5 V DC (Digital inputs, 12 V DC)
Condition 0: ≤ 5 V DC (Digital inputs, 24 V DC)
Condition 1: ≥ 15 V DC (Digital inputs, 24 V DC)
Condition 1: ≥ 8 V DC (Digital inputs, 12 V DC)
Condition 0: ≤ 5 V AC (Digital inputs, 24 V AC)
Condition 1: ≥ 15 V AC (Digital inputs, 24 V AC)
Making/breaking capacity
3600/360 VA (AC, at B 300)
28/28 VA (DC, at R 300)
Number of inputs (analog)
0
Number of inputs (digital)
8
Number of outputs (analog)
0
Number of outputs (digital)
8
Output
8 Relay Outputs
min. recommended load: 12 V AC/DC > 500 mA
Parallel switching
Not permitted

Güvenlik

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Power supply + Inputs + right Extension interface against Outputs: yes
POW+Inputs+right Extension interface vs. left Extension interface: yes
Outputs against left Extension interface: yes
Outputs against each other: yes
Protection against polarity reversal
Yes
Safe isolation
Relay outputs: 300 V AC, Between two contacts
Relay outputs: 300 V AC, Between coil and contact

Kısa devre değeri

Short-circuit protection
≥ 1A (T), Fuse, Power supply

Terminal Kapasiteleri

Screwdriver size
3.5 x 0.6 mm, Terminal screw
Terminal capacity
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm², flexible with ferrule
0.2 - 2.5 mm², flexible without ferrule
Tightening torque
0.6 Nm, Screw terminals

Ürün teknik özelliklerini aktar

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Ürünü Doğrula

16 veya 17 haneli seri numaranızı girin.
Girdiğiniz seri numarası özel karakter içermemelidir. Girdiğiniz seri numarası doğru değil, seri numarası 16 veya 17 haneli olmalıdır. Girdiğiniz seri numarası bulunamadı. Lütfen tekrar deneyin veya Bu sorunu bildir daha fazla destek için. Girdiğiniz seri numarası ürünle eşleşmiyor. Girdiğiniz seri numarası ürünle eşleşmiyor. Tıkla buraya Girdiğiniz seri numarasına ait ürün sayfasına gitmek için… Bu seri numarası Eaton tarafından şüpheli olarak tanımlanmıştır, lütfen tekrar deneyin veya… Bu sorunu bildir daha fazla destek için.
Seri numarası
Sıfırla Bu seri numarası Eaton tarafından şüpheli olarak tanımlanmıştır, lütfen tekrar deneyin veya… Bu sorunu bildir daha fazla destek için. Bu seri numarası Eaton tarafından tanınmıyor ve geçersiz. Lútfen bu formu kullanın Bu sorunu bildir daha fazla destek için.
6 haneli doğrulama kodunu girin.
Girdiğiniz ürün şüpheli görünüyor! Lütfen tekrar deneyin veya Bu sorunu bildir daha fazla destek için. Girdiğiniz doğrulama kodu bu seri numarası için kayıtlarımızla eşleşmiyor. Lütfen tekrar deneyin veya Bu sorunu bildir daha fazla destek için. Geçersiz Doğrulama kodu. Doğrulama kodu 6 haneden oluşmalıdır. Bu sorunu bildir daha fazla destek için. Doğrulama kodu gereklidir Bu sorunu bildir daha fazla destek için.
Doğrulama işleminden önce, Captcha güvenlik doğrulamasını tamamlayın.
Bize Ulaşın Bir sorunu bildirmek için
x
Sorun Bildirin
Lütfen tam adınızı girin.
x
Teşekkür ederiz, talebiniz alındı. Ürün ekibimiz sizinle kısa süre içinde iletişime geçecek.
Not: .zip indirmesinde dosya(lar) eksikse dosya türü toplu indirme tarafından desteklenmiyor demektir.