Eaton DC1 Variable frequency drive, 400 V AC, 3-phase, 4.1 A, 1.5 kW, IP66/NEMA 4X, Radio interference suppression filter, Brake chopper, 7-digital display assembly, Additional PCB protection, UV resistant, FS2
| Product Name | 
                                                Eaton DC1 Variable frequency drive
                                             | 
| Catalog Number | 
                                                199433
                                             | 
| EAN | 
                                                4015081978229
                                             | 
| Product Length/Depth | 
                                                182 mm
                                             | 
| Product Height | 
                                                257 mm
                                             | 
| Product Width | 
                                                188 mm
                                             | 
| Product Weight | 
                                                3.5 kg
                                             | 
| Certifications | 
                                                EAC  CSA-C22.2 No. 14 IEC/EN 61800-5-1 UL Listed Certified by UL for use in Canada UL report applies to both US and Canada UkrSEPRO IEC/EN 61800-3 UL File No.: E172143 CE marking CE UL IEC/EN61800-5 UL Category Control No.: NMMS, NMMS7 CUL RCM RoHS, ISO 9001 IEC/EN 61800-2 UL 508C | 
| Catalog Notes | 
 | 
| Model Code | 
                                                DC1-344D1FB-A66OE1
                                             | 
| Features | 
                                                Parameterization: Keypad  Parameterization: drivesConnect mobile (App) Parameterization: Fieldbus Parameterization: drivesConnect | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Fitted with: | 
                                                Radio interference suppression filter  Brake chopper Control unit 7-digital display assembly Internal DC link PC connection IGBT inverter UV resistance Breaking resistance Additional PCB protection | 
| Climatic proofing | 
                                                < 95 average relative humidity (RH), no condensation, no corrosion
                                             | 
| Connection to SmartWire-DT | 
                                                No
                                             | 
| Operating mode | 
                                                BLDC motors  PM motors U/f control Speed control with slip compensation Sensorless vector control (SLV) Synchronous reluctance motors | 
| Rated impulse withstand voltage (Uimp) | 
                                                2000 V
                                             | 
| Frame size | 
                                                FS2
                                             | 
| Altitude | 
                                                Above 1000 m with 1 % derating per 100 m  Max. 4000 m | 
| Application in domestic and commercial area permitted | 
                                                Yes
                                             | 
| Mains switch-on frequency | 
                                                Maximum of one time every 30 seconds
                                             | 
| Ambient operating temperature - max | 
                                                40 °C
                                             | 
| Ambient operating temperature - min | 
                                                -20 °C
                                             | 
| Mains voltage - max | 
                                                480 V
                                             | 
| Output voltage - max | 
                                                500 V
                                             | 
| Relative symmetric net frequency tolerance | 
                                                10 %
                                             | 
| Relative symmetric net voltage tolerance | 
                                                10 %
                                             | 
| Ambient storage temperature - max | 
                                                60 °C
                                             | 
| Ambient storage temperature - min | 
                                                -40 °C
                                             | 
| Apparent power at 400 V | 
                                                2.84 kVA
                                             | 
| Apparent power at 480 V | 
                                                3.41 kVA
                                             | 
| Application in industrial area permitted | 
                                                Yes
                                             | 
| Product category | 
                                                Variable frequency drives
                                             | 
| Protection | 
                                                Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
                                             | 
| Resolution | 
                                                0.1 Hz (Frequency resolution, setpoint value)
                                             | 
| Switch-on threshold for the braking transistor | 
                                                780 VDC
                                             | 
| Voltage rating - max | 
                                                480 V
                                             | 
| Mounting position | 
                                                Vertical
                                             | 
| Overvoltage category | 
                                                III
                                             | 
| Communication interface | 
                                                Modbus RTU, built in  OP-Bus (RS485), built in CANopen®, built in SmartWire-DT, optional | 
| Converter type | 
                                                U converter
                                             | 
| Degree of protection | 
                                                NEMA 4X  IP66 | 
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 
                                                2 HP
                                             | 
| Braking resistance | 
                                                250 Ω
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Heat dissipation per pole, current-dependent Pvid | 
                                                0 W
                                             | 
| Input current ILN at 150% overload | 
                                                5.6 A
                                             | 
| Mains current distortion | 
                                                120 %
                                             | 
| Protocol | 
                                                Other bus systems  CAN MODBUS EtherNet/IP | 
| Overload current IL at 150% overload | 
                                                6.15 A
                                             | 
| Rated frequency - max | 
                                                62 Hz
                                             | 
| Rated frequency - min | 
                                                48 Hz
                                             | 
| Rated operational power at 380/400 V, 50 Hz, 3-phase | 
                                                1.5 kW
                                             | 
| Assigned motor current IM at 400 V, 50 Hz, 150% overload | 
                                                3.6 A
                                             | 
| Assigned motor current IM at 440 - 480 V, 60 Hz, 150% overload | 
                                                3.4 A
                                             | 
| System configuration type | 
                                                AC supply systems with earthed center point
                                             | 
| Braking current | 
                                                ≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake
                                             | 
| Electromagnetic compatibility | 
                                                1st and 2nd environments (according to EN 61800-3)
                                             | 
| Braking torque | 
                                                Max. 100 % of rated operational current Ie with external braking resistor - Main circuit  Max. 100 % of rated operational current Ie, variable, DC - Main circuit Max. 30 % MN, Standard - Main circuit | 
| Cable length | 
                                                300 m, unscreened, with motor choke, maximum permissible, Motor feeder  C2 ≤ 5 m, maximum motor cable length 100 m, screened, maximum permissible cable length 200 m, screened, with motor choke, maximum permissible cable length 150 m, unscreened, maximum permissible cable length C3 ≤ 25 m, maximum motor cable length | 
| Functions | 
                                                4-quadrant operation possible
                                             | 
| Output voltage (U2) | 
                                                480 V AC, 3-phase  400 V AC, 3-phase | 
| Delay time | 
                                                < 10 ms, On-delay  < 10 ms, Off-delay | 
| Number of inputs (analog) | 
                                                2 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA)
                                             | 
| Number of inputs (digital) | 
                                                4 (parameterizable, 10 - 30 V DC)
                                             | 
| Radio interference class | 
                                                Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments  C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. | 
| Number of outputs (digital) | 
                                                1
                                             | 
| Starting current - max | 
                                                175 % IH
                                             | 
| Number of phases (input) | 
                                                3
                                             | 
| Number of relay outputs | 
                                                1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
                                             | 
| Number of phases (output) | 
                                                3
                                             | 
| Power consumption | 
                                                66.5 W
                                             | 
| Rated control supply voltage | 
                                                10 V DC (Us, max. 10 mA)
                                             | 
| Efficiency | 
                                                97 % (η)
                                             | 
| Supply frequency | 
                                                50/60 Hz
                                             | 
| Leakage current at ground IPE - max | 
                                                12.6 mA
                                             | 
| Mains voltage - min | 
                                                380 V
                                             | 
| Nominal output current I2N | 
                                                4.1 A
                                             | 
| Number of HW-interfaces (industrial ethernet) | 
                                                0
                                             | 
| Number of HW-interfaces (other) | 
                                                0
                                             | 
| Number of HW-interfaces (parallel) | 
                                                0
                                             | 
| Number of HW-interfaces (RS-232) | 
                                                0
                                             | 
| Number of HW-interfaces (RS-422) | 
                                                0
                                             | 
| Number of HW-interfaces (RS-485) | 
                                                1
                                             | 
| Number of HW-interfaces (serial TTY) | 
                                                0
                                             | 
| Number of HW-interfaces (USB) | 
                                                0
                                             | 
| Number of interfaces (PROFINET) | 
                                                0
                                             | 
| Number of outputs (analog) | 
                                                1
                                             | 
| Output at linear load at rated output voltage - max | 
                                                1.5 kW
                                             | 
| Output at quadratic load at rated output voltage - max | 
                                                1.5 kW
                                             | 
| Output frequency - max | 
                                                500 Hz
                                             | 
| Output frequency - min | 
                                                0 Hz
                                             | 
| Short-circuit protection (external output circuits) | 
                                                Type 1 coordination via the power bus' feeder unit, Main circuit
                                             | 
| Suitable for | 
                                                Branch circuits, (UL/CSA)
                                             | 
| Switching frequency | 
                                                8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
                                             | 
| Rated operational current (Ie) | 
                                                4.1 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
                                             | 
| Rated operational voltage | 
                                                400 V AC, 3-phase  480 V AC, 3-phase | 
| Short-circuit protection rating | 
                                                6 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
                                             | 
| Heat dissipation at current/speed | 
                                                29 W at 25% current and 0% speed  31 W at 25% current and 50% speed 31 W at 50% current and 0% speed 35 W at 50% current and 50% speed 39 W at 100% current and 0% speed 41 W at 50% current and 90% speed 47 W at 100% current and 50% speed 55 W at 100% current and 90% speed |