192523
NZMN2-MX90-NA

Eaton Moeller series Molded case circuit breaker, PXR20, Electronic, NZMN2, 90 A, Three-pole, 690 V, Screw connection, UL/CSA

Generelle spesifikasjoner

Product Name
Eaton Moeller series NZM molded case circuit breaker electronic
Catalog Number
192523
EAN
4015081932511
Product Length/Depth
149 mm
Product Height
195 mm
Product Width
105 mm
Product Weight
2.509 kg
Compliances
RoHS conform
Certifications
CE marking
CSA-C22.2 No. 5-09
UL 489
UL listed
UL508
Specially designed for North America
CSA (Class No. 1432-01)
UL (File No. E31593)
CSA certified
IEC 60947-2
CSA (File No. 22086)
UL/CSA
UL (Category Control Number DIVQ)
IEC
Model Code
NZMN2-MX90-NA

Ytterligere informasjon

Functions
Phase failure sensitive
Current limiting circuit breaker
Motor protection

Leveringsprogram

Amperage Rating
90 A
Application
Branch circuits, feeder circuits
Circuit breaker frame type
NZM2
Fitted with:
Thermal protection
Number of poles
Three-pole
Release system
Electronic release
Special features
  • Rated current = rated uninterrupted current: 90 A
  • Switches conform to UL/CSA as well as the IEC regulations. IEC switching performance values are contained on the rating plate.
Type
Circuit breaker

Designverifisering etter IEC/EN 61439

10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.

Designverifisering etter IEC/EN 61439 – Tekniske data

Ambient operating temperature - max
70 °C
Ambient storage temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - min
40 °C
Equipment heat dissipation, current-dependent
6.68 W
Rated operational current for specified heat dissipation (In)
90 A

Technical data - electrical

Amperage Rating
90 A
Direction of incoming supply
As required
Electrical connection type of main circuit
Screw connection
Handle type
Rocker lever
Instantaneous current setting (Ii) - max
1620 A
Instantaneous current setting (Ii) - min
180 A
Overload current setting (Ir) - max
90 A
Overload current setting (Ir) - min
36 A
Rated insulation voltage (Ui)
690 V
Rated operating power at AC-3, 230 V
22 kW
Rated operating power at AC-3, 400 V
45 kW
Rated operating voltage Ue (UL) - max
480 V
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
150 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz
150 kA
Short-circuit release non-delayed setting - max
1260 A
Short-circuit release non-delayed setting - min
180 A
Voltage rating
690 V - 690 V

Technical data - mechanical

Degree of protection
IP20
Mounting Method
Fixed
Built-in device fixed built-in technique
Special features
  • Rated current = rated uninterrupted current: 90 A
  • Switches conform to UL/CSA as well as the IEC regulations. IEC switching performance values are contained on the rating plate.
Switch off technique
Electronic

Eksporter produktspesifikasjoner

Serial Number Verified :
Authenticated: ✓
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Autentiser produktet

Skriv inn ditt serienummer på 16-17 siffer
Serienummeret du oppgir kan ikke inneholde spesialtegn. Serienummeret du har oppgitt er feil, det må bestå av 16 eller 17 siffer. Finner ikke serienummeret du har oppgitt. Prøv på nytt eller rapporter dette problemet for å få hjelp. Serienummeret du har oppgitt samsvarer ikke med produktet. Kontroller produktets serienummer og prøv på nytt. Klikke her for å gå til produktsiden for serienummeret du har oppgitt Serienummeret er kjent for Eaton for å være mistenkelig, prøv på nytt eller rapporter dette problemet for å få hjelp.
Serienummer
Tilbakestill Serienummeret er kjent for Eaton for å være mistenkelig, prøv på nytt eller rapporter dette problemet for å få hjelp. Serienummeret gjenkjennes ikke av Eaton og er ugyldig. Bruk dette skjemaet for å rapporter dette problemet for å få hjelp.
Oppgi den sekssifrede autentiseringskoden
Produktet du har oppgitt er mistenkelig! Prøv på nytt eller rapporter dette problemet for å få hjelp. Autentiseringskoden du har oppgitt samsvarer ikke med våre registreringer for dette serienummeret. Prøv på nytt eller rapporter dette problemet for å få hjelp. Ugyldig autentiseringskode. Lengden må være seks tegn rapporter dette problemet for å få hjelp. Autentiseringskode kreves rapporter dette problemet for å få hjelp.
Fullfør Captcha-utfordringen før du autentiserer.
x
Rapporter et problem
Oppgi fullt navn.
x
Takk, problemet er registrert og produktteamet vårt kontakter deg snart.