Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim CB LGE3400FAGC, CU wndng, DOE2016, NEMA2, FR943SD, 220°C, 112.5 kVA, E-S shld, Fl/wll mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @2.5%, 4 @-2.5%, 150°C, 112.5 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, Copper windings, NEMA 2, FR943SD, 60 Hz, 220°C, 112.5 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 112.5 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integrated ventilated transformer, Aluminum windings, NEMA 2, FR943SD, 60 Hz, 220°C, 112.5 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 112.5 kVA, 480 Vac-208Y/120 Vac, 280BPB, DOE 2016
Eaton Breaker integrated ventilated transformer, Aluminum windings, NEMA 2, FR943SD, 60 Hz, 220°C, 112.5 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 112.5 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB NGS3080KSEC, CU wndng, DOE2016, NEMA2, FR944SD, 220°C, 225 kVA, E-S shld, Flr mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 225 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, Copper windings, NEMA 2, FR944SD, 60 Hz, 220°C, 225 kVA, Floor, Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 225 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB NGS3080KSEC, AL wndng, DOE2016, NEMA2, FR944SD, 220°C, 225 kVA, E-S shld, Flr mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 225 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, K-f 1 sec MCCB NGS3080KSEC, AL wndng, DOE2016, NEMA2, FR944SD, 220°C, 225 kVA, E-S shld, Flr mt, 3-ph, PV: 480V delta, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 225 kVA, 280BSB
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB NGS3120KSEC, CU wndng, DOE2016, NEMA2, FR945SD, 220°C, 300 kVA, E-S shld, Flr mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 300 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, K-f 1 sec MCCB NGS3120KSEC, CU wndng, DOE2016, NEMA2, FR945SD, 220°C, 300 kVA, E-S shld, Flr mt, 3-ph, PV: 480V delta, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 300 kVA, 280BSB
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB NGS3120KSEC, AL wndng, DOE2016, NEMA2, FR945SD, 220°C, 300 kVA, E-S shld, Flr mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 300 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, K-f 1 sec MCCB NGS3120KSEC, AL wndng, DOE2016, NEMA2, FR945SD, 220°C, 300 kVA, E-S shld, Flr mt, 3-ph, PV: 480V delta, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 300 kVA, 280BSB
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB JGE3160FAGC, CU wndng, DOE2016, NEMA2, FR940SD, 220°C, 45 kVA, E-S shld, Fl/wall mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 45 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, Copper windings, NEMA 2, FR940SD, 60 Hz, 220°C, 45 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 45 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integrated ventilated transformer, Aluminum windings, NEMA 2, FR940SD, 60 Hz, 220°C, 45 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 45 kVA, 480 Vac-208Y/120 Vac, 280BPB, DOE 2016
Eaton Breaker integrated ventilated transformer, Aluminum windings, NEMA 2, FR940SD, 60 Hz, 220°C, 45 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 45 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB LGE3500FAGC, CU wndng, DOE2016, NEMA2, FR943SD, 220°C, 150 kVA, E-S shld, Fl/wall mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @+2.5%, 4 @-2.5%, 150°C, 150 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, Copper windings, NEMA 2, FR943SD, 60 Hz, 220°C, 150 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 150 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integrated ventilated transformer, Aluminum windings, NEMA 2, FR943SD, 60 Hz, 220°C, 150 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 150 kVA, 480 Vac-208Y/120 Vac, 280BPB, DOE 2016
Eaton Breaker integrated ventilated transformer, Aluminum windings, NEMA 2, FR943SD, 60 Hz, 220°C, 150 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 150 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB JGE3250FAGC, CU wndng, DOE2016, NEMA2, FR942SD, 220°C, 75 kVA, E-S shld, Fl/wall mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 75 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, Copper windings, NEMA 2, FR942SD, 60 Hz, 220°C, 75 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 75 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016
Eaton Breaker integr@ed ventil@ed transformer, K-f 1 prim MCCB JGE3250FAGC, AL wndng, DOE2016, NEMA2, FR942SD, 220°C, 75 kVA, E-S shld, Fl/wall mt, 3-ph, PV: 480V dlt, SV: 208Y/120, NEMA ST-20, 2 @ +2.5%, 4 @ -2.5%, 150°C, 75 kVA, 280BPB
Eaton Breaker integrated ventilated transformer, Aluminum windings, NEMA 2, FR942SD, 60 Hz, 220°C, 75 kVA , Three-phase, 480 Delta V, 208Y/120 Vac, NEMA ST-20, 150°C, 75 kVA, 480 Vac-208Y/120 Vac, 280BSB, DOE 2016