Eaton Moeller series IZMX/INX - ACB. Circuit-breaker, 3 pole, 800A, 85 kA, Selective operation, IEC, Withdrawable
| Product Name | 
                                                Eaton Moeller series IZMX/INX circuit-breaker
                                             | 
| Catalog Number | 
                                                183734
                                             | 
| EAN | 
                                                4015081794706
                                             | 
| Product Length/Depth | 
                                                584 mm
                                             | 
| Product Height | 
                                                597 mm
                                             | 
| Product Width | 
                                                521 mm
                                             | 
| Product Weight | 
                                                69 kg
                                             | 
| Compliances | 
                                                IEC  IEC/EN 60947 RoHS conform | 
| Model Code | 
                                                IZMX40N3-V08W-1
                                             | 
| Type | 
 | 
| Number of poles | 
                                                Three-pole
                                             | 
| Amperage Rating | 
                                                800 A
                                             | 
| Release system | 
                                                Electronic release
                                             | 
| Features | 
                                                Motor drive optional  Complete device with protection unit | 
| Special features | 
 | 
| Frame | 
                                                IZMX40
                                             | 
| Fitted with: | 
                                                Switched-off indicator
                                             | 
| Used with | 
                                                Air circuit breakers/switch-disconnector  Open circuit breaker | 
| Voltage rating at AC | 
                                                690 V AC
                                             | 
| Rated operating voltage (Ue) - min | 
                                                690 V
                                             | 
| Rated operating voltage (Ue) - max | 
                                                690 V
                                             | 
| Rated insulation voltage (Ui) | 
                                                1000 V
                                             | 
| Rated impulse withstand voltage (Uimp) | 
                                                12 kV AC
                                             | 
| Rated uninterrupted current (Iu) | 
                                                800 A
                                             | 
| Rated uninterrupted current (Iu) at 50°C | 
                                                800 A
                                             | 
| Rated uninterrupted current (Iu) at 60°C | 
                                                800 A
                                             | 
| Rated uninterrupted current (Iu) at 70°C | 
                                                800 A
                                             | 
| Rated short-time withstand current (t = 1 s) | 
                                                85 kA
                                             | 
| Rated short-time withstand current at 50/60 Hz (t = 3 s) | 
                                                66 kA
                                             | 
| Overload release current setting - min | 
                                                320 A
                                             | 
| Overload release current setting - max | 
                                                800 A
                                             | 
| Short-circuit release delayed setting - min | 
                                                600 A
                                             | 
| Short-circuit release delayed setting - max | 
                                                8000 A
                                             | 
| Short-circuit release non-delayed setting | 
                                                1.5 - 10 x Ir
                                             | 
| Short-circuit release non-delayed setting - min | 
                                                0 A
                                             | 
| Short-circuit release non-delayed setting - max | 
                                                12000 A
                                             | 
| Adjustment range short-term delayed short-circuit release - min | 
                                                480 A
                                             | 
| Adjustment range short-term delayed short-circuit release - max | 
                                                8000 A
                                             | 
| Adjustment range undelayed short-circuit release - min | 
                                                1600 A
                                             | 
| Adjustment range undelayed short-circuit release - max | 
                                                12000 A
                                             | 
| Rated short-circuit breaking capacity at 400 V, 50 Hz | 
                                                85 kA
                                             | 
| Rated short-circuit making capacity up to 440 V, 50/60 Hz | 
                                                187 kA
                                             | 
| Rated short-circuit making capacity up to 690 V, 50/60 Hz | 
                                                166 kA
                                             | 
| Power of withdrawable switch with cassette | 
                                                35 W
                                             | 
| Closing delay via spring release | 
                                                35 ms
                                             | 
| Electrical connection type of main circuit | 
                                                Rail connection
                                             | 
| Number of standard mechanical operations per hour - max | 
                                                60
                                             | 
| Operating sequence up to 690 V, 50/60 Hz (IEC/EN 60947) | 
                                                75 kA
                                             | 
| Actuator type | 
                                                Push button
                                             | 
| Utilization category | 
                                                B
                                             | 
| Overvoltage category | 
                                                III
                                             | 
| Pollution degree | 
                                                3
                                             | 
| Lifespan, electrical | 
                                                20000 operations (switching cycles ON/OFF, with maintenance)  10000 operations (switching capacity) | 
| Direction of incoming supply | 
                                                As required
                                             | 
| Device construction | 
                                                Built-in device slide-in technique (withdrawable)
                                             | 
| Mounting Method | 
                                                Withdrawable
                                             | 
| Mounting Method | 
                                                Withdrawable
                                             | 
| Degree of protection | 
                                                IP31 with door seals  IP55 with protective cover IP31 | 
| Protection | 
                                                Selective operation
                                             | 
| Number of auxiliary contacts (change-over contacts) | 
                                                2
                                             | 
| Number of auxiliary contacts (normally closed contacts) | 
                                                0
                                             | 
| Number of auxiliary contacts (normally open contacts) | 
                                                0
                                             | 
| Position of connection for main current circuit | 
                                                Back side
                                             | 
| Weight of cassette version (3-pole) | 
                                                29 kg
                                             | 
| Weight of fixed withdrawable version (3-pole) | 
                                                69 kg
                                             | 
| Lifespan, mechanical | 
                                                12500 switching cycles (ON/OFF)  25000 operations (switching capacity, with maintenance) | 
| Terminal capacity (copper bar) | 
                                                60 mm x 10 mm (1x) for withdrawable units (black)
                                             | 
| Rated operational current for specified heat dissipation (In) | 
                                                800 A
                                             | 
| Equipment heat dissipation, current-dependent | 
                                                35 W
                                             | 
| Ambient operating temperature details | 
                                                -20 °C - 70 °C
                                             | 
| Ambient operating temperature - min | 
                                                -20 °C
                                             | 
| Ambient operating temperature - max | 
                                                70 °C
                                             | 
| Ambient storage temperature - min | 
                                                -20 °C
                                             | 
| Ambient storage temperature - max | 
                                                70 °C
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             |