Eaton Moeller® series Rapid Link - Reversing starter, 6.6 A, Sensor input 4, Actuator output 2, 400/480 V AC, PROFINET, HAN Q4/2, with manual override switch
| Product Name | 
                                            
                                            
                                             
                                                Eaton Rapid Link Reversing starter
                                             
                                         | 
                                    
| Catalog Number | 
                                            
                                            
                                             
                                                199140
                                             
                                         | 
                                    
| EAN | 
                                            
                                            
                                             
                                                4015081971985
                                             
                                         | 
                                    
| Product Length/Depth | 
                                            
                                            
                                             
                                                120 mm
                                             
                                         | 
                                    
| Product Height | 
                                            
                                            
                                             
                                                270 mm
                                             
                                         | 
                                    
| Product Width | 
                                            
                                            
                                             
                                                220 mm
                                             
                                         | 
                                    
| Product Weight | 
                                            
                                            
                                             
                                                1.83 kg
                                             
                                         | 
                                    
| Certifications | 
                                            
                                            
                                             
                                                RoHS  
                                        IEC/EN 60947-4-2 CCC CE UL approval UL 60947-4-2  | 
                                    
| Catalog Notes | 
                                            
                                            
                                             
                                                Assigned motor rating: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm at 50 Hz or 1800 min at 60 Hz
                                             
                                         | 
                                    
| Model Code | 
                                            
                                            
                                             
                                                RAMO5-W424PNT-412RS1
                                             
                                         | 
                                    
| Type | 
                                            
                                            
                                             
                                                Reversing starter
                                             
                                         | 
                                    
| Features | 
                                            
                                            
                                             
                                                Parameterization: Keypad  
                                        Parameterization: drivesConnect mobile (App) Parameterization: drivesConnect Parameterization: Fieldbus  | 
                                    
| 10.10 Temperature rise | 
                                            
                                            
                                             
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             
                                         | 
                                    
| 10.11 Short-circuit rating | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.12 Electromagnetic compatibility | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.13 Mechanical function | 
                                            
                                            
                                             
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             
                                         | 
                                    
| 10.2.2 Corrosion resistance | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.5 Lifting | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.6 Mechanical impact | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.7 Inscriptions | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.3 Degree of protection of assemblies | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.4 Clearances and creepage distances | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.5 Protection against electric shock | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.6 Incorporation of switching devices and components | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.7 Internal electrical circuits and connections | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.8 Connections for external conductors | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.2 Power-frequency electric strength | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.3 Impulse withstand voltage | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.4 Testing of enclosures made of insulating material | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| Fitted with: | 
                                            
                                            
                                             
                                                Manual override switch  
                                        Key switch position AUTO Key switch position OFF/RESET 2 Actuator outputs Thermistor monitoring PTC Electronic motor protection Key switch position HAND Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Thermo-click Short-circuit release  | 
                                    
| Class | 
                                            
                                            
                                             
                                                CLASS 10 A
                                             
                                         | 
                                    
| Lifespan, electrical | 
                                            
                                            
                                             
                                                10,000,000 Operations (at AC-3)
                                             
                                         | 
                                    
| Climatic proofing | 
                                            
                                            
                                             
                                                < 95 %, no condensation  
                                        In accordance with IEC/EN 50178  | 
                                    
| Rated impulse withstand voltage (Uimp) | 
                                            
                                            
                                             
                                                4000 V
                                             
                                         | 
                                    
| Model | 
                                            
                                            
                                             
                                                Reversing starter
                                             
                                         | 
                                    
| Altitude | 
                                            
                                            
                                             
                                                Max. 2000 m  
                                        Max. 1000 m Above 1000 m with 1 % performance reduction per 100 m  | 
                                    
| Lifespan, mechanical | 
                                            
                                            
                                             
                                                10,000,000 Operations (at AC-3)
                                             
                                         | 
                                    
| Mains switch-on frequency | 
                                            
                                            
                                             
                                                Maximum of one time every 60 seconds
                                             
                                         | 
                                    
| Electrical connection type of main circuit | 
                                            
                                            
                                             
                                                Plug-in connection
                                             
                                         | 
                                    
| Mains voltage tolerance | 
                                            
                                            
                                             
                                                380 - 480 V (-15 %/+10 %, at 50/60 Hz)
                                             
                                         | 
                                    
| Voltage type | 
                                            
                                            
                                             
                                                DC
                                             
                                         | 
                                    
| Mounting position | 
                                            
                                            
                                             
                                                Vertical
                                             
                                         | 
                                    
| Rated conditional short-circuit current (Iq) | 
                                            
                                            
                                             
                                                10 kA
                                             
                                         | 
                                    
| Overvoltage category | 
                                            
                                            
                                             
                                                III
                                             
                                         | 
                                    
| Connection | 
                                            
                                            
                                             
                                                Connections pluggable in power section
                                             
                                         | 
                                    
| Off-delay | 
                                            
                                            
                                             
                                                20 - 35 ms
                                             
                                         | 
                                    
| Functions | 
                                            
                                            
                                             
                                                For actuation of motors with mechanical brake  
                                        External reset possible Temperature compensated overload protection  | 
                                    
| On-delay | 
                                            
                                            
                                             
                                                20 - 35 ms
                                             
                                         | 
                                    
| System configuration type | 
                                            
                                            
                                             
                                                AC voltage  
                                        Phase-earthed AC supply systems are not permitted. Center-point earthed star network (TN-S network)  | 
                                    
| Braking current | 
                                            
                                            
                                             
                                                ≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake
                                             
                                         | 
                                    
| Electromagnetic compatibility | 
                                            
                                            
                                             
                                                Class A
                                             
                                         | 
                                    
| Current limitation | 
                                            
                                            
                                             
                                                0.3 - 6.6 A, motor, main circuit  
                                        Adjustable, motor, main circuit  | 
                                    
| Output frequency | 
                                            
                                            
                                             
                                                50/60 Hz
                                             
                                         | 
                                    
| Braking voltage | 
                                            
                                            
                                             
                                                400/480 V AC -15 % / +10 %, Actuator for external motor brake
                                             
                                         | 
                                    
| Overload cycle | 
                                            
                                            
                                             
                                                AC-53a
                                             
                                         | 
                                    
| Overload release current setting - min | 
                                            
                                            
                                             
                                                0.3 A
                                             
                                         | 
                                    
| Rated conditional short-circuit current (Iq), type 2, 230 V | 
                                            
                                            
                                             
                                                0 A
                                             
                                         | 
                                    
| Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V | 
                                            
                                            
                                             
                                                0 A
                                             
                                         | 
                                    
| Rated conditional short-circuit current, type 1, 480 Y/277 V | 
                                            
                                            
                                             
                                                10000 A
                                             
                                         | 
                                    
| Rated conditional short-circuit current, type 1, 600 Y/347 V | 
                                            
                                            
                                             
                                                0 A
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated frequency - max | 
                                            
                                            
                                             
                                                63 Hz
                                             
                                         | 
                                    
| Rated frequency - min | 
                                            
                                            
                                             
                                                47 Hz
                                             
                                         | 
                                    
| Rated operational current (Ie) at 150% overload | 
                                            
                                            
                                             
                                                6.6 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 
                                            
                                            
                                             
                                                6.6 A
                                             
                                         | 
                                    
| Shock resistance | 
                                            
                                            
                                             
                                                15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft
                                             
                                         | 
                                    
| Protocol | 
                                            
                                            
                                             
                                                PROFINET IO
                                             
                                         | 
                                    
| Rated control voltage (Uc) | 
                                            
                                            
                                             
                                                400/480 V AC (external brake 50/60 Hz)  
                                        24 V DC (-15 %/+20 %, external via AS-Interface® plug)  | 
                                    
| Supply frequency | 
                                            
                                            
                                             
                                                50/60 Hz, fLN, Main circuit
                                             
                                         | 
                                    
| Rated operational current (Ie) | 
                                            
                                            
                                             
                                                6.6 A
                                             
                                         | 
                                    
| Rated operational power at 380/400 V, 50 Hz - max | 
                                            
                                            
                                             
                                                3 kW
                                             
                                         | 
                                    
| Rated operational power at 380/400 V, 50 Hz - min | 
                                            
                                            
                                             
                                                0.09 kW
                                             
                                         | 
                                    
| Rated operational voltage | 
                                            
                                            
                                             
                                                480 V AC, 3-phase  
                                        400 V AC, 3-phase  | 
                                    
| Short-circuit protection (external output circuits) | 
                                            
                                            
                                             
                                                Type 1 coordination via the power bus' feeder unit, Main circuit
                                             
                                         | 
                                    
| Vibration | 
                                            
                                            
                                             
                                                Resistance: 6 Hz, Amplitude 0.15 mm  
                                        Resistance: 57 Hz, Amplitude transition frequency on acceleration Resistance: 10 - 150 Hz, Oscillation frequency Resistance: According to IEC/EN 60068-2-6  | 
                                    
| Ambient operating temperature - max | 
                                            
                                            
                                             
                                                55 °C
                                             
                                         | 
                                    
| Ambient operating temperature - min | 
                                            
                                            
                                             
                                                -10 °C
                                             
                                         | 
                                    
| Ambient storage temperature - max | 
                                            
                                            
                                             
                                                70 °C
                                             
                                         | 
                                    
| Ambient storage temperature - min | 
                                            
                                            
                                             
                                                -40 °C
                                             
                                         | 
                                    
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                3 HP
                                             
                                         | 
                                    
| Number of auxiliary contacts (normally closed contacts) | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of auxiliary contacts (normally open contacts) | 
                                            
                                            
                                             
                                                2
                                             
                                         | 
                                    
| Number of command positions | 
                                            
                                            
                                             
                                                2
                                             
                                         | 
                                    
| Number of pilot lights | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Overload release current setting - max | 
                                            
                                            
                                             
                                                6.6 A
                                             
                                         | 
                                    
| Rated operational power at AC-3, 220/230 V, 50 Hz | 
                                            
                                            
                                             
                                                0 kW
                                             
                                         | 
                                    
| Rated operational power at AC-3, 380/400 V, 50 Hz | 
                                            
                                            
                                             
                                                3 kW
                                             
                                         | 
                                    
| Rated power at 460 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                2.238 kW
                                             
                                         | 
                                    
| Rated power at 575 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                0 kW
                                             
                                         | 
                                    
| Product category | 
                                            
                                            
                                             
                                                Motor starter
                                             
                                         | 
                                    
| Cable length | 
                                            
                                            
                                             
                                                10 m, Radio interference level, maximum motor cable length
                                             
                                         | 
                                    
| Coordination class (IEC 60947-4-3) | 
                                            
                                            
                                             
                                                Class 1
                                             
                                         | 
                                    
| Degree of protection | 
                                            
                                            
                                             
                                                NEMA 12  
                                        IP65  | 
                                    
| Electrical connection type for auxiliary- and control-current circuit | 
                                            
                                            
                                             
                                                Plug-in connection
                                             
                                         | 
                                    
| Input current | 
                                            
                                            
                                             
                                                6.6 A (at 150 % Overload)
                                             
                                         | 
                                    
| Power consumption | 
                                            
                                            
                                             
                                                8 W
                                             
                                         |