Automatic transfer switches

Contactor type automatic transfer switches

Eaton’s contactor type automatic transfer switches (ATS) are designed to quickly and reliably transition critical loads between preferred and alternate/generator power sources. Ideal for use in NFPA 70 emergency, legally required, optional standby, and critical operations systems that demand reliable performance.

Continuous Current Rating
Up to 3000 A
System Voltage Rating
Up to 600 Vac
System Frequency Rating
50/60 Hz

Core features

  • Available in open delayed, open in-phase, and closed transition types
  • Automatic and non-automatic modes of operation 
  • Includes an interlocked, double-throw power switch driven by a robust solenoid operating mechanism
  • Service entrance rated option available with Eaton’s Arcflash Reduction Maintenance System to reduce the incident energy levels for downstream equipment during periods of maintenance
  • Indoor and outdoor enclosure types
  • Listed to UL 1008 and CSA 22.2 No. 178, Seismic certified
  • Integrated Cam-Lok receptacle power panel that serves as a docking station for quick connection of a portable or temporary generator 
ats-900-en-us.jpg

The Value of a SMART ATS Controller

Intelligent controllers can help you make informed decisions and perform efficient maintenance related to your automatic transfer switch (ATS) activity

Eaton offers controller models that allow for remote management, advanced diagnostics, programmable setpoints, integral metering and innovative features such as ATS Health and Maintenance Watch™ - available with the ATC-900

Generator Docking Station

Eaton’s contactor type transfer switches can be equipped with an integrated Cam-Lok receptacle power panel that serves as a docking station for quick connection of a portable or temporary generator to supply critical electrical loads with emergency power during a utility outage.

View full screen

 

Transfer switches: Keep critical power on

Contactor type transfer switches configured with Cam-Lok receptacles can serve as a docking station for quick connection of a temporary generator.
eaton-ats-cam-lok-infographic-mz140007EN-gray-500x500.jpg

Automatic transfer switches

Reliable, rugged, versatile and compact assemblies for transferring essential loads and electrical distribution systems from one power source to another.


Watch the following videos to learn more:

  • What is WCR in automatic transfer switches?
  • Choosing a transfer switch
  • Recent change to National Electric code
  • UL1008 Short-circuit WCRs

    switch-to-eaton-should-be-automatic-500x500.jpg

    Finding the right ATS has never been easier

    Learn about the broadest range of ATSs available in today’s critical power market

    Learn more about automatic transfer switches

    Transfer switch 101

    Read the introductory guide to picking the right transfer switch for your environment

    Monitoring the integrity of the engine generator remote start circuit in an emergency system

    See an overview of recent changes in the National Electrical Code (NEC) pertaining to a generator remote start circuit for use in an emergency system and provides a code-compliant solution that can be implemented with one or more transfer switches using common technology.

    blue-prints-architecture-business-cropped.jpg
    Specifications

    Ratings

    CONTINUOUS CURRENT Up to 3000 A
    SYSTEM VOLTAGE Up to 600 Vac
    SYSTEM FREQUENCY 50/60 Hz
    SHORT-CIRCUIT WITHSTAND AND CLOSE-ON (TIME BASED) Up to 100 kA (0.05 sec)
    SHORT-CIRCUIT WITHSTAND AND CLOSE-ON (SPECIFIC BREAKER) Up to 100 kA
    SHORT-CIRCUIT WITHSTAND AND CLOSE-ON (SPECIFIC FUSE CLASS) Up to 200 kA
    SHORT-TIME WITHSTAND AND CLOSE-ON (TIME-BASED) Up to 85 kA (0.5 sec)

    Standards

    THIRD-PARTY APPROVAL/RECOGNITION UL 1008 and CSA 22.2 No. 178 Listed
    NEMA 1, 3R, 12, 4X
    SEISMIC QUALIFICATION IBC, CBC, UBC Zone 4, OSHPD
    EMISSIONS FCC Part 15 (Subpart B); CISPR 11
    ELECTROMAGNETIC COMPATIBILITY (EMC)

    IEC 61000-4-2: electrostatic discharge immunity

    IEC 61000-4-3: radiated immunity

    IEC 61000-4-4: fast transient/burst immunity

    IEC 61000-4-5: surge immunity

    IEC 61000-4-6: conducted immunity

    IEC 61000-4-11: voltage dip/interruption immunity

    Devices

    SWITCHING MECHANISM Double-throw power switch
    CIRCUIT PROTECTION (SERVICE ENTRANCE RATED) 310+ Electronic Trip Unit
    SAFETY (SERVICE ENTRANCE RATED TRANSFER SWITCHES) Arcflash Reduction Maintenance System 
    SURGE PROTECTION Surge Protective Devices
    POWER AND ENERGY METERS Power Xpert meters

    Enclosure

    ENCLOSURE TYPE Indoor and outdoor
    ACCESS (CATALOG DEPENDENT) Front/rear 
    CABLE ENTRY (CATALOG DEPENDENT) Top/bottom
    MOUNTING (CATALOG DEPENDENT)
    Wall/floor