Foto je ilustrační
Download
Eaton Distribution parts. Low-voltage h.b.c fuse switch strip, 160A, 500V/160A, 690V/160A, size 00, 60mm
Product Name |
Eaton Distribution parts
|
Catalog Number |
106211
|
EAN |
4015081059812
|
Product Length/Depth |
455 mm
|
Product Height |
136 mm
|
Product Width |
50 mm
|
Product Weight |
1.46 kg
|
Compliances |
RoHS conform
|
Model Code |
NH-SLS-00/160-60
|
Used with |
25 mm x 5/10 mm rail
15 mm x 5/10 mm rail 12 mm x 5/10 mm rail 20 mm x 5/10 mm rail 30 mm x 5/10 mm rail Triple T profile Double T profile 60 mm system Busbar fuse material |
Number of poles |
Three-pole
|
Frame |
00
|
Frequency rating |
50 Hz - 60 Hz
|
Voltage rating at AC |
|
Pollution degree |
3
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Screw diameter for flange connection |
M8
|
Admissible heat dissipation (NH-SE) - max |
12 W
|
Ambient operating temperature - max |
40 °C
|
Ambient operating temperature - min |
-5 °C
|
Conventional thermal current Ith of auxiliary contacts (1-pole, open) |
160 A
|
Fuse current rating at 500 V - max |
160 A
|
Heat dissipation at Ith AC without NH-SE |
20 W
|
Operating altitude without derating - max |
2000 mm
|
Rated insulation voltage (Ui) |
1000 V
|
Rated operating voltage (Ue) at AC - max |
690 V
|
Rated operational current (gL/gG) - max |
160 A
|
Rated uninterrupted current (Iu) |
160 A
|
Rated impulse withstand voltage (Uimp) |
8 kV
|
Construction size (fuse inserts) |
NH00
|
Connection |
Top or bottom
|
Direction of incoming supply |
As required
|
Distance between busbar centers |
60 mm
|
Electrical connection type of main circuit |
Rail connection
|
Mounting position |
Vertical or horizontal
|
Release indication |
None
|
Suitable for |
Double T profile
Triple T profile Combi-base for busbar mounting (12 - 30 mm) x 5/10 mm Combi-base for direct busbar mounting |
Rated conditional short-circuit current (Iq) |
50 kA
50 kA at AC (effective) |
Functions |
Uninterrupted operation (Control mode)
Low-voltage h.b.c. switch-fuse unit |
Overvoltage category |
III
|
Frequency rating of contacts |
50 Hz - 60 Hz
|
Degree of protection |
IP30 (operating state)
IP30 IP10 (front cover open) |
Rated operation current (Ie) |
160 A
|
Voltage rating |
400 V AC
|
Distance between rail centers |
60 mm
|
Type |
|
Special features |
|
Model |
Fuse switch disconnector
|
Fuse current rating at 690 V - max |
160 A
|
Lifespan, electrical |
200 operations
|
Lifespan, mechanical |
1400 operations
|
Terminal capacity (cable) |
9 mm x 0.8 mm (6x) at box terminal
|
Permitted heat loss from fuse links - max |
20 W at 160 A
|
Terminal capacity (copper busbar) |
Max. 20 mm x 8 mm for flat busbar at flange connection
|
Terminal capacity (copper band) |
9 mm x 0.8 mm (6x) at box terminal
|
Terminal capacity (stranded cable) |
1.5 mm² - 70 mm² (1x) at box terminal
70 mm² (1x) at flange connection |
Rated operational current |
160 A (AC-21B)
125 A / 160 A (AC-23B) 160 A (AC-22B) |