Eaton Moeller series NZM - Molded Case Circuit Breaker. Auxiliary contact, 2early N/O, operates as an early-make contact, 2/3
Product Name |
Eaton Moeller series NZM auxiliary contact
|
Catalog Number |
259430
|
EAN |
4015082594305
|
Product Length/Depth |
42 mm
|
Product Height |
90 mm
|
Product Width |
30 mm
|
Product Weight |
0.076 kg
|
Compliances |
RoHS conform
|
Certifications |
UL listed
CSA-C22.2 No. 5-09 CSA certified IEC60947 UL489 CSA (File No. 22086) CSA (Class No. 1437-01) UL (File No. E140305) UL (Category Control Number DIHS) CE marking |
Model Code |
NZM2/3-XHIV
|
Used with |
FAZ-B6 (max. miniature circuit breaker)
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Mounting Method |
Other
|
Connection type |
Screw connection
|
Conventional thermal current Ith of auxiliary contacts |
4 A
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
2
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
4 A
|
Voltage rating at AC |
500 V AC
|
Voltage rating at DC |
220 VDC
|
Number of fault-signal switches |
0
|
Rated operational current |
2.5 A at 240 V AC (UL/CSA)
1 A at 250 V DC (UL/CSA) |
Fuse short-circuit protection - max |
10 A gG/gL
|
Model |
Integrable
|
Terminal capacity (solid/flexible conductor) |
0.75 mm² - 2.5 mm² (2x) at auxiliary contacts with ferrule
18 - 14 AWG (2x) at auxiliary contacts 0.75 mm² - 2.5 mm² (1x) at auxiliary contacts with ferrule 18 - 14 AWG (1x) at auxiliary contacts |
Lamp holder |
None
|
Special features |
C300/R300 (auxiliary contacts, UL/CSA, pilot duty)
|