Eaton Moeller® series RMQ16 Selector switch, 3 positions, white, momentary Q25WK3
Product Name |
Eaton Moeller® series RMQ16 Changeover switch
|
Catalog Number |
072372
|
EAN |
4015080723721
|
Product Length/Depth |
65 mm
|
Product Height |
25 mm
|
Product Width |
25 mm
|
Product Weight |
0.015 kg
|
Certifications |
CSA-C22.2 No. 14-05
IEC/EN 60947 CE IEC/EN 60947-5 UL 508 CSA Class No.: 3211-03 CSA File No.: 46552 UL UL File No.: E29184 CSA UL Category Control No.: NKCR |
Model Code |
Q25WK3
|
Bezel color |
Black
|
Bezel material |
Plastic
|
Design |
With thumb-grip
|
Fitted with: |
Front ring
VS anti-rotation tab |
Degree of protection |
NEMA 1
|
Degree of protection (front side) |
IP65
|
Lifespan, mechanical |
3,000,000 Operations
|
Opening diameter |
16 mm
|
Operating frequency |
1800 Operations/h
|
Operating torque |
0.2 Nm
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
RMQ16
|
Rated impulse withstand voltage (Uimp) |
800 V AC
|
Size |
Front dimensions: 25 × 25 mm
|
Switching angle |
45 °
|
Terminal capacity |
0.5 - 1.0 mm²
|
Terminal size |
2.8 x 0.8 mm to DIN 46247 and IEC 60760, Fast-on connectors
2.8 x 0.8 mm to DIN 46244, Blade terminal |
Type |
Selector switch actuator
|
Mounting position |
As required
|
Shock resistance |
Mechanical, According to IEC/EN 60068-2-27
40 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms |
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature (enclosed) - min |
25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Rated insulation voltage (Ui) |
250 V
|
Rated operational voltage (Ue) at AC - max |
24 V
|
Actuator color |
White
|
Actuator function |
Spring-return
Momentary |
Actuator type |
Toggle
|
Number of switch positions |
3
|
Connection to SmartWire-DT |
No
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
Not applicable.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|