Eaton EU5E SmartWire-DT I/O module, 24 V DC, 4 AI configurable Pt100 / Pt1000: -100 - +400°C, Ni1000: -50 - +200 °C
Product Name |
Eaton EU5E Accessory Input module
|
Catalog Number |
172560
|
EAN |
4015081691050
|
Product Length/Depth |
102 mm
|
Product Height |
90 mm
|
Product Width |
35 mm
|
Product Weight |
0.16 kg
|
Certifications |
CSA File No.: 2324643
CSA Class No.: 3211-07 UL File No.: E29184 IEC/EN 61131-2 UL UL Category Control No.: NKCR CSA |
Model Code |
EU5E-SWD-4PT-2
|
Electric connection type |
Flat plug-in connection
|
Features |
Fieldbus connection over separate bus coupler possible
Analog outputs configurable Input, resistance thermometer Analog inputs configurable |
Fitted with: |
Temperature sensors PT100, PT1000 and Ni1000
Display mode for temperatures (°C, °F, raw value) |
Functions |
Adjustable parameter settings
For connection of analog I/O signals |
Current consumption |
22 mA, SmartWire-DT network
|
Degree of protection |
IP20
NEMA 1 |
Mounting method |
Rail mounting possible
Wall mounting/direct mounting Top-hat rail fixing (according to IEC/EN 60715, 35 mm) |
Overvoltage category |
II
|
Pollution degree |
2
|
Product category |
SmartWire-DT slave
|
Repetition accuracy |
0.5 % (Temperature inputs)
|
Residual ripple |
≤ 5 % (input voltage)
|
Terminal capacity |
0.25 - 1.5 mm² (24 - 16 AWG), flexible with ferrule, Terminal for I/O sensor
0.2 - 1.5 mm² (AWG 24 - 16), solid, Terminal for I/O sensor |
Type |
Analog modules
|
Voltage type |
DC
|
Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
Mounting position |
As required
|
Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
Air pressure |
795 - 1080 hPa (operation)
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
70 °C
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2 |
Environmental conditions |
Condensation: prevent with appropriate measures
|
Operating temperature - min |
-100 °C
|
Operating temperature - max |
55 °C
|
Relative humidity |
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
Burst impulse |
2 kV, Signal cable, according to IEC/EN 61131-2, Level 3
2 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3 2 kV, Supply cable, according to IEC/EN 61131-2, Level 3 |
Contact discharge |
4 kV, according to IEC/EN 61131-2, Level 2, ESD
|
Electromagnetic fields |
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008) 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008) |
Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
Radio interference class |
Class B (EN 55011)
|
Surge rating |
1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
1 kV, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC |
Power loss |
0.6 W
|
Rated operational voltage |
24 V DC (-15 %/+ 20 % - power supply)
|
Supply voltage at AC, 50 Hz - min |
0 VAC
|
Supply voltage at AC, 50 Hz - max |
0 VAC
|
Supply voltage at DC - min |
0 VDC
|
Supply voltage at DC - max |
0 VDC
|
Connection to SmartWire-DT |
Yes
|
Connection type |
Pin contact, 8 pole
Push in terminals, Supply and I/O sensor Connector: external device plug SWD4-8SF2-5, SmartWire-DT |
Data transfer rate |
Setting automatically
250 kBit/s, SmartWire-DT |
LED indicator |
Status indication of SmartWire-DT network: Green LED
|
Protocol |
Other bus systems
|
Station |
SmartWire-DT slave, SmartWire-DT network
|
Conversions |
250 ms, Temperature inputs
|
Input |
Inputs, configurable (PT100, PT1000, Ni1000)
|
Number of inputs (analog) |
4
|
Number of outputs (analog) |
0
|
Resolution |
0.1 °C, Temperature inputs
|
Total error |
± 1 %, Temperature Inputs
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Potential isolation |
Inputs for SmartWire-DT: yes
|
Protection against polarity reversal |
Yes
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
0.6 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|