Ladda ner dokument () av 20
Normprodukter och effektbrytare

PFIM Type F xPole Residual Current Circuit Breaker

Eaton offers a complete range of compact residual current devices for fault current/residual current and additional protection, suitable for residential and small commercial use. Type F is a special variant of type A with altered frequency characteristics. The Type F RCD complies with IEC/EN 62423 and provides safe and reliable protection against sinusoidal residual currents and pulsating DC fault currents. It is also capable of handling residual currents with mixed frequencies of up to 1 kHz (10, 50, 1000 Hz) as defined with the IEC/EN 62423.

Compliant to
IEC/EN 62423
current withstand capability
3 kA
DC residual currents
up to 10 mA

Viktiga egenskaper

  • Increased protection in applications with 1-phase frequency converter due to the detection of mixed frequencies
  • Reduction of nuisance tripping thanks to
    - time delayed tripping
    - increased current withstand capability > 3 kA
  • Higher load rating with DC residual currents up to 10 mA
  • Comprehensive range of accessories
  • Real contact position indicator
  • Automatic re-setting possible (by automatic reclosing device)
  • Shape compatible with and suitable for standard busbar connection to other devices of the P-series
  • Twin-purpose terminal (lift/open-mouthed) above and below
  • Busbar positioning optionally above or below
  • Free terminal space despite installed busbar
  • Universal tripping signal switch, also suitable for PLS., PKN., Z-A. can be mounted subsequently
  • Auxiliary switch Z-HK can be mounted subsequently
  • Contact position indicator red - green
  • Delayed types suitable for use with standard fluorescent lamps, with or without electronic ballast (30mA-RCD: 30 units per phase conductor)
  • The device functions irrespective of the position of installation
  • Line voltage-independent tripping
  • Mains connection at either side
  • The 4-pole device can also be used for 2- or 3-pole connection

Reliable protection for machines

These products provide an optimal system and additional protection against residual earth leakage currents for a wide range of applications by offering different tripping characteristics to cater for various electrical systems and components that can generate. Available in a comprehensive range of nominal current values and with optional accessories.

Suitable type

Tripping is line voltage-independent. Consequently, the RCD is suitable for “fault current/residual current protection” and “additional protection” within the the meaning of the applicable installation rules.

Increased protection in applications

Increased protection in applications with 1-phase frequency converter due to the detection of mixed frequencies and higher load capacity with smooth DC fault currents up to 10 mA.