Bilden är representativ
Download
Eaton Distribution parts. Low-voltage h.b.c fuse switch strip, 160A, 500V/160A, 690V/160A, size 00, NH-SLS-00/160
| Product Name |
Eaton Distribution parts
|
| Catalog Number |
106210
|
| EAN |
4015081059805
|
| Product Length/Depth |
455 mm
|
| Product Height |
120 mm
|
| Product Width |
50 mm
|
| Product Weight |
1.43 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC/EN 60947-3
|
| Model Code |
NH-SLS-00/160
|
| Used with |
Z-…SAD
120 mm x 10 mm rail 40 mm x 10 mm rail Triple T profile 100 mm x 10 mm rail 60 mm x 10 mm rail Z-…SADD 50 mm x 10 mm rail 30 mm x 10 mm rail Double T profile 80 mm x 10 mm rail Busbar fuse material 185 mm system |
| Number of poles |
Three-pole
|
| Frame |
00
|
| Frequency rating |
50 Hz - 60 Hz
|
| Voltage rating at AC |
|
| Pollution degree |
3
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Screw diameter for flange connection |
M8
|
| Admissible heat dissipation (NH-SE) - max |
12 W
|
| Ambient operating temperature - max |
40 °C
|
| Ambient operating temperature - min |
-5 °C
|
| Conventional thermal current Ith of auxiliary contacts (1-pole, open) |
160 A
|
| Fuse current rating at 500 V - max |
160 A
|
| Heat dissipation at Ith AC without NH-SE |
20 W
|
| Operating altitude without derating - max |
2000 mm
|
| Rated insulation voltage (Ui) |
1000 V
|
| Rated operating voltage (Ue) at AC - max |
690 V
|
| Rated operational current (gL/gG) - max |
160 A
|
| Rated uninterrupted current (Iu) |
160 A
|
| Rated impulse withstand voltage (Uimp) |
8 kV
|
| Construction size (fuse inserts) |
NH00
|
| Connection |
Top or bottom
|
| Direction of incoming supply |
As required
|
| Distance between busbar centers |
100 mm
|
| Electrical connection type of main circuit |
Rail connection
|
| Mounting position |
Vertical or horizontal
|
| Release indication |
None
|
| Rated conditional short-circuit current (Iq) |
50 kA at AC (effective)
50 kA |
| Functions |
Uninterrupted operation (Control mode)
Low-voltage h.b.c. switch-fuse unit |
| Overvoltage category |
III
|
| Frequency rating of contacts |
50 Hz - 60 Hz
|
| Degree of protection |
IP30 (operating state)
IP10 (front cover open) IP30 |
| Rated operation current (Ie) |
160 A
|
| Voltage rating |
400 V AC
|
| Distance between rail centers |
100 mm
185 mm |
| Type |
|
| Special features |
|
| Model |
Fuse switch disconnector
|
| Fuse current rating at 690 V - max |
160 A
|
| Lifespan, electrical |
200 operations
|
| Lifespan, mechanical |
1400 operations
|
| Terminal capacity (cable) |
9 mm x 0.8 mm (6x) at box terminal
|
| Permitted heat loss from fuse links - max |
20 W at 160 A
|
| Terminal capacity (copper busbar) |
Max. 20 mm x 10 mm for flat busbar at flange connection
|
| Terminal capacity (copper band) |
9 mm x 0.8 mm (6x) at box terminal
|
| Terminal capacity (stranded cable) |
70 mm² (1x) at flange connection
1.5 mm² - 70 mm² (1x) at box terminal |
| Rated operational current |
160 A (AC-21B)
125 A / 160 A (AC-23B) 160 A (AC-22B) |
| Screw connection for busbars |
M8
Only in combination with adapter for … x 5/10 |