Eaton Moeller® series M22 Contact element, Cage Clamp, Front fixing, 2 N/O, 24 V 3 A, 220 V 230 V 240 V 4 A
Product Name |
Eaton Moeller® series M22 Accessory Contact element
|
Catalog Number |
107898
|
EL Number |
3767023
|
EAN |
4015081075355
|
Product Length/Depth |
43 mm
|
Product Height |
10 mm
|
Product Width |
38 mm
|
Product Weight |
0.012 kg
|
Compliances |
CE Marked
|
Certifications |
CSA Std. C22.2 No. 14-05
EN 60947-5 CSA Std. C22.2 No. 94-91 UL 508 IEC 60947-5 CSA CE CSA Class No.: 3211-03 IEC/EN 60947-5 UL CSA File No.: 012528 CSA-C22.2 No. 14-05 CSA-C22.2 No. 94-91 UL/CSA IEC IEC 60947-5-1 UL File No.: E29184 UL Category Control No.: NKCR |
Model Code |
M22-CK20
|
Electric connection type |
Spring clamp connection
|
Degree of protection |
IP20
|
Model |
Top mounting and integrable
|
Mounting method |
Front fastening
|
Operating frequency |
3600 Operations/h
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
Accessories
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Type |
Auxiliary contact
|
Used with |
Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.
Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker. Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker. Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker. Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker. |
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
70 °C
|
Ambient storage temperature - min |
-25 °C
|
Ambient storage temperature - max |
85 °C
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Terminal capacity (AWG) |
1 x (20 - 18)
2 x (20 - 18) |
Terminal capacity (flexible with ferrule) |
0.5 - 1.5 mm²
|
Terminal capacity (solid) |
0.5 - 1.5 mm²
|
Terminal capacity (solid/flexible with ferrule) |
1 x (0,5 - 1,5) mm²
2 x (0,5 - 0,75) mm² |
Terminal capacity (stranded) |
0.5 - 1.5 mm²
|
Conventional thermal current Ith of auxiliary contacts (1-pole, open) |
4 A
|
Rated insulation voltage (Ui) |
250 V
|
Rated operational current (Ie) at AC-15, 115 V |
4 A
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
6 A
|
Rated operational current (Ie) at DC-13, 110 V |
0.6 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0.3 A
|
Rated operational current (Ie) at DC-13, 24 V |
3 A
|
Rated operational current (Ie) at DC-13, 60 V |
1 A
|
Rated operational voltage (Ue) at AC - max |
230 V
|
Rated operational voltage (Ue) at DC - max |
220 V
|
Short-circuit protection |
PKZM0-10/FAZ-B6/1, Contacts, Max. short-circuit protective device, Fuseless
|
Short-circuit protection rating |
Max. 10 A gG/gL, Fuse, Contacts
Max. 10 A gG/gL, Fuse, Auxiliary contacts |
Connection to SmartWire-DT |
No
|
Connection type |
Front fixing
Double contact Cage Clamp |
Actuating force - max |
10 N
|
Control circuit reliability |
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA) |
Force for positive opening - min |
0 N
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
2
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.05 W
|
Rated operational current for specified heat dissipation (In) |
4 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|