Eaton SWD4 Feeder module, SmartWire-DT, supply for contactors/cards of a local SWD segment
| Product Name |
Eaton SWD4 Accessory Power supply
|
| Catalog Number |
168880
|
| EAN |
4015081653713
|
| Product Length/Depth |
45 mm
|
| Product Height |
90 mm
|
| Product Width |
72 mm
|
| Product Weight |
0.105 kg
|
| Certifications |
IEC/EN 61131-2
EN 50178 |
| Catalog Notes |
SWD power supply module for modules (IP20) on a local SWD segment
|
| Model Code |
SWD4-FFR-PF1-1
|
| Electric connection type |
Flat plug-in connection
|
| Features |
Fieldbus connection over separate bus coupler possible
|
| Fitted with: |
Power supply module
|
| Degree of protection |
IP20
|
| Mounting method |
Rail mounting possible
Wall mounting/direct mounting Top-hat rail fixing (according to IEC/EN 60715, 35 mm) Screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
| Mounting method |
Rail mounting possible
Wall mounting/direct mounting Top-hat rail fixing (according to IEC/EN 60715, 35 mm) Screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
| Product category |
SmartWire-DT accessories
|
| Suitable as |
Segment module
|
| Type |
SWD power supply module
|
| Voltage type |
DC
|
| Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
| Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
| Mounting position |
As required
|
| Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
| Air pressure |
795 - 1080 hPa (operation)
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature - max |
55 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Ambient storage temperature - max |
70 °C
|
| Climatic proofing |
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3 |
| Environmental conditions |
Condensation: prevent with appropriate measures
|
| Operating temperature - min |
-25 °C
|
| Operating temperature - max |
55 °C
|
| Relative humidity |
0 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
| Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
| Contact discharge |
4 kV, according to IEC/EN 61131-2, Level 2, ESD
|
| Power loss |
Normally 2.6 W
|
| Supply voltage at AC, 50 Hz - min |
0 VAC
|
| Supply voltage at AC, 50 Hz - max |
0 VAC
|
| Supply voltage at DC - min |
20.4 VDC
|
| Supply voltage at DC - max |
28.8 VDC
|
| Connection to SmartWire-DT |
Yes
|
| Connection type |
Push in terminals
SWD: Plug, 8-pole |
| Protocol |
Other bus systems
|
| Number of insertion cycles |
200
|
| Explosion safety category for dust |
None
|
| Explosion safety category for gas |
None
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Static heat dissipation, non-current-dependent Pvs |
2.6 W
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|