Eaton Moeller® series M22 Combination of contact element and self-monitoring contact element M22-K01SMC10, M22-A mounting adapter, and M22-XSMC signaling contact actuator, 3 NC
Product Name |
Eaton Moeller® series M22 Accessory Contact element
|
Catalog Number |
180794
|
EAN |
4015081759637
|
Product Length/Depth |
40.2 mm
|
Product Height |
32.5 mm
|
Product Width |
16 mm
|
Product Weight |
0.024 kg
|
Certifications |
IEC 60947-5-1
|
Model Code |
M22-AFK03SMC10
|
Electric connection type |
Spring clamp connection
|
Degree of protection |
IP20
|
Lifespan, mechanical |
1,000,000 Operations (AC operated)
|
Model |
Top mounting
|
Mounting method |
Front fastening
|
Operating frequency |
3600 Operations/h
|
Overvoltage category |
III
|
Pollution degree |
3
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Shock resistance |
50 g, Mechanical, Shock duration 11 ms
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
70 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
85 °C
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 Dry heat to IEC 60068-2-2 |
Terminal capacity (flexible with ferrule) |
2 x (0.25 - 1) mm²
Use WAGO Variocrimp 4 crimping tool; please enquire for others |
Terminal capacity (solid) |
2 x 1 (075 - 1.5) mm², Can be plugged without tools
2 x (0.2 - 1.5) mm² |
Terminal capacity (solid/stranded AWG) |
2 x (24 - 16)
|
Rated insulation voltage (Ui) |
250 V
|
Rated operational current (Ie) |
4 A at AC-15, 60 V
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
1.5 A
|
Rated operational current (Ie) at AC-15, 24 V |
4 A
|
Rated operational current (Ie) at DC-13, 110 V |
0.4 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0.2 A
|
Rated operational current (Ie) at DC-13, 24 V |
1.5 A
|
Rated operational current (Ie) at DC-13, 60 V |
0.8 A
|
Rated conditional short-circuit current (Iq) |
1 kA
|
Short-circuit protection |
FAZ-B4, Contacts, Max. short-circuit protective device, Fuseless
|
Short-circuit protection rating |
Max. 4 A gG/gL, Fuse, Contacts
|
Connection to SmartWire-DT |
No
|
Connection type |
Front fixing
Push-in clamp Cage Clamp |
Actuating force - max |
13.5 N
|
Actuator travel and actuation force (DIN EN 60947-5-1) |
5.5 mm
|
Knob travel |
5.8 mm
|
Force for positive opening - min |
60 N
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
1
|