Eaton Moeller® series DILMT Power contactor, 3 pole, 380 V 400 V: 5.5 kW, 24 V 50/60 Hz, AC operation, Screw terminals
Product Name |
Eaton Moeller® series DILMT Contactor
|
Catalog Number |
197615
|
EAN |
4015081944941
|
Product Length/Depth |
77.5 mm
|
Product Height |
70.1 mm
|
Product Width |
27 mm
|
Product Weight |
0.175 kg
|
Certifications |
GB14048
IEC/EN 60947 EN 60335-1 |
Catalog Notes |
Also tested according to AC-3e.
|
Model Code |
DILMT12(24V50/60HZ)
|
Number of poles |
Three-pole
|
Application |
Contactors for Motors
|
Connection |
Screw terminals
|
Connection to SmartWire-DT |
No
|
Degree of protection |
IP20
|
Frame size |
FS1
|
Lifespan, electrical |
1,000,000 Operations (at 400V, AC-3)
|
Lifespan, mechanical |
10,000,000 Operations (AC operated)
|
Operating frequency |
3600 mechanical Operations/h (AC operated)
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
Contactors
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Suitable for |
Also motors with efficiency class IE3
|
Used with |
DILT-XHI…
|
Utilization category |
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
Voltage type |
AC
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
80 °C
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Terminal capacity (solid) |
1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm² |
Terminal capacity (stranded) |
1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm² |
Stripping length (main cable) |
14 mm
|
Screw size |
M3.5, Terminal screw
|
Screwdriver size |
2, Terminal screw, Pozidriv screwdriver
2, Terminal screw, Control circuit cables, Pozidriv screwdriver |
Tightening torque |
0.8 Nm, Screw terminals
|
Rated breaking capacity at 380/400 V |
96 A
|
Rated insulation voltage (Ui) |
690 V
|
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
20 A
|
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
12 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
12 A
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
5.5 kW
|
Rated operational voltage (Ue) at AC - max |
660 V
|
Pick-up voltage |
0.85 - 1.1 V AC x Uc
|
Power consumption, pick-up, 50 Hz |
35 VA, Dual-frequency coil in a cold state and 1.0 x Us
0 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, pick-up, 60 Hz |
0 VA, Dual-frequency coil in a cold state and 1.0 x Us
35 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, sealing, 50 Hz |
2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
0 W, Dual-frequency coil in a cold state and 1.0 x Us 2.3 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz |
Power consumption, sealing, 60 Hz |
0 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
2.1 W, Dual-frequency coil in a cold state and 1.0 x Us 0 W, Dual-frequency coil in a cold state and 1.0 x Us 6 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
24 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|