Eaton DC1 Variable frequency drive, 230 V AC, 1-phase, 7 A, 0.75 kW, IP66/NEMA 4X, Radio interference suppression filter, 7-digital display assembly, Additional PCB protection, UV resistant, FS1
Product Name |
Eaton DC1 Variable frequency drive
|
Catalog Number |
199389
|
EAN |
4015081977789
|
Product Length/Depth |
162 mm
|
Product Height |
232 mm
|
Product Width |
161 mm
|
Product Weight |
2.5 kg
|
Certifications |
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3 CE UkrSEPRO IEC/EN 61800-5-1 Certified by UL for use in Canada EAC UL 508C UL File No.: E172143 RCM UL report applies to both US and Canada CUL IEC/EN 61800-2 UL CE marking UL Listed CSA-C22.2 No. 14 IEC/EN61800-5 RoHS, ISO 9001 |
Model Code |
DC1-S27D0FN-A66OE1
|
Features |
Parameterization: Keypad
Parameterization: drivesConnect mobile (App) Parameterization: drivesConnect Parameterization: Fieldbus |
Fitted with: |
Control unit
7-digital display assembly Radio interference suppression filter Additional PCB protection UV resistance Internal DC link IGBT inverter PC connection |
Cable length |
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length 75 m, unscreened, maximum permissible, Motor feeder 150 m, unscreened, with motor choke, maximum permissible, Motor feeder 50 m, screened, maximum permissible, Motor feeder C1 ≤ 1 m, maximum motor cable length 100 m, screened, with motor choke, maximum permissible, Motor feeder |
Communication interface |
OP-Bus (RS485), built in
Modbus RTU, built in CANopen®, built in SmartWire-DT, optional |
Connection to SmartWire-DT |
No
|
Degree of protection |
IP66
NEMA 4X |
Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
Frame size |
FS1
|
Mounting position |
Vertical
|
Product category |
Variable frequency drives
|
Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
Protocol |
CAN
MODBUS Other bus systems EtherNet/IP |
Radio interference class |
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments C1: for conducted emissions only |
Suitable for |
Branch circuits, (UL/CSA)
|
Altitude |
Max. 4000 m
Above 1000 m with 1 % derating per 100 m |
Ambient operating temperature - min |
-20 °C
|
Ambient operating temperature - max |
40 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
60 °C
|
Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
Efficiency |
97 % (η)
|
Input current ILN at 150% overload |
9.3 A
|
Leakage current at ground IPE - max |
2.49 mA
|
Mains switch-on frequency |
Maximum of one time every 30 seconds
|
Mains voltage - min |
200 V
|
Mains voltage - max |
240 V
|
Operating mode |
Speed control with slip compensation
BLDC motors PM motors U/f control Sensorless vector control (SLV) Synchronous reluctance motors |
Output frequency - min |
0 Hz
|
Output frequency - max |
500 Hz
|
Output voltage (U2) |
230 V AC, single-phase
240 V AC, single-phase |
Overload current IL at 150% overload |
10.5 A
|
Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
Rated frequency - min |
48 Hz
|
Rated frequency - max |
62 Hz
|
Rated operational current (Ie) |
7 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
|
Rated operational voltage |
230 V AC, 1-phase
240 V AC, 1-phase |
Resolution |
0.1 Hz (Frequency resolution, setpoint value)
|
Short-circuit protection rating |
15 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|
Starting current - max |
175 % IH
|
Supply frequency |
50/60 Hz
|
Switching frequency |
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
|
System configuration type |
AC supply systems with earthed center point
|
Voltage rating - max |
240 V
|
Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload |
6.8 A
|
Assigned motor current IM at 230 V, 50 Hz, 150% overload |
7 A
|
Assigned motor power at 230/240 V, 60 Hz, 1-phase |
1 HP
|
Apparent power at 230 V |
1.61 kVA
|
Apparent power at 240 V |
1.68 kVA
|
Braking torque |
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
|
Number of inputs (analog) |
2
|
Number of inputs (digital) |
4
|
Number of outputs (analog) |
1
|
Number of outputs (digital) |
1
|
Number of relay outputs |
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
|