Eaton DC1 Variable frequency drive, 230 V AC, 1-phase, 10.5 A, 1.1 kW, IP66/NEMA 4X, Radio interference suppression filter, Brake chopper, 7-digital display assembly, Local controls, Additional PCB protection, UV resistant, FS2
Product Name |
Eaton DC1 Variable frequency drive
|
Catalog Number |
199392
|
EAN |
4015081977819
|
Product Length/Depth |
182 mm
|
Product Height |
257 mm
|
Product Width |
188 mm
|
Product Weight |
3.5 kg
|
Certifications |
CE marking
RoHS, ISO 9001 UL Category Control No.: NMMS, NMMS7 CE RCM IEC/EN 61800-5-1 UL 508C UL UkrSEPRO Certified by UL for use in Canada CUL UL File No.: E172143 UL Listed CSA-C22.2 No. 14 IEC/EN 61800-2 EAC IEC/EN 61800-3 IEC/EN61800-5 UL report applies to both US and Canada |
Model Code |
DC1-S2011FB-A6SOE1
|
Features |
Parameterization: Fieldbus
Parameterization: Keypad Parameterization: drivesConnect mobile (App) Parameterization: drivesConnect |
Fitted with: |
Breaking resistance
Radio interference suppression filter 7-digital display assembly Internal DC link PC connection IGBT inverter UV resistance Additional PCB protection Control unit Local controls Brake chopper |
Functions |
4-quadrant operation possible
|
Cable length |
200 m, screened, with motor choke, maximum permissible cable length
C3 ≤ 25 m, maximum motor cable length 100 m, screened, maximum permissible cable length C2 ≤ 5 m, maximum motor cable length 300 m, unscreened, with motor choke, maximum permissible, Motor feeder C1 ≤ 1 m, maximum motor cable length 150 m, unscreened, maximum permissible cable length |
Communication interface |
CANopen®, built in
SmartWire-DT, optional Modbus RTU, built in OP-Bus (RS485), built in |
Connection to SmartWire-DT |
No
|
Degree of protection |
NEMA 4X
IP66 |
Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
Frame size |
FS2
|
Mounting position |
Vertical
|
Product category |
Variable frequency drives
|
Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
Protocol |
CAN
MODBUS Other bus systems EtherNet/IP |
Radio interference class |
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments C1: for conducted emissions only |
Suitable for |
Branch circuits, (UL/CSA)
|
Altitude |
Above 1000 m with 1 % derating per 100 m
Max. 4000 m |
Ambient operating temperature - min |
-20 °C
|
Ambient operating temperature - max |
40 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
60 °C
|
Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
Efficiency |
97 % (η)
|
Input current ILN at 150% overload |
14 A
|
Leakage current at ground IPE - max |
2.49 mA
|
Mains switch-on frequency |
Maximum of one time every 30 seconds
|
Mains voltage - min |
200 V
|
Mains voltage - max |
240 V
|
Operating mode |
U/f control
PM motors Sensorless vector control (SLV) Speed control with slip compensation Synchronous reluctance motors BLDC motors |
Output frequency - min |
0 Hz
|
Output frequency - max |
500 Hz
|
Output voltage (U2) |
240 V AC, single-phase
230 V AC, single-phase |
Overload current IL at 150% overload |
15.75 A
|
Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
Rated frequency - min |
48 Hz
|
Rated frequency - max |
62 Hz
|
Rated operational current (Ie) |
10.5 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
|
Rated operational voltage |
230 V AC, 1-phase
240 V AC, 1-phase |
Resolution |
0.1 Hz (Frequency resolution, setpoint value)
|
Short-circuit protection rating |
25 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|
Starting current - max |
175 % IH
|
Supply frequency |
50/60 Hz
|
Switching frequency |
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
|
System configuration type |
AC supply systems with earthed center point
|
Voltage rating - max |
240 V
|
Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload |
9.6 A
|
Assigned motor current IM at 230 V, 50 Hz, 150% overload |
10.5 A
|
Assigned motor power at 230/240 V, 60 Hz, 1-phase |
1.5 HP
|
Apparent power at 230 V |
2.42 kVA
|
Apparent power at 240 V |
2.52 kVA
|
Braking resistance |
100 Ω
|
Braking torque |
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit |
Switch-on threshold for the braking transistor |
390 VDC
|
Number of inputs (analog) |
2
|
Number of inputs (digital) |
4
|
Number of outputs (analog) |
1
|
Number of outputs (digital) |
1
|
Number of relay outputs |
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
|