Reset
Eaton Moeller series NZM - Molded Case Circuit Breaker. Switch-disconnector 4p, 400A, BT
Product Name |
Eaton Moeller series NZM switch-disconnector
|
Catalog Number |
111653
|
EAN |
4015081112135
|
Product Length/Depth |
166 mm
|
Product Height |
275 mm
|
Product Width |
185 mm
|
Product Weight |
6.94 kg
|
Compliances |
RoHS conform
|
Certifications |
IEC/EN 60947
IEC |
Model Code |
PN3-4-400-BT
|
Application |
Use in unearthed supply systems at 690 V
|
Type |
Switch-disconnector
|
Circuit breaker frame type |
PN4
|
Number of poles |
Four-pole
|
Features |
Version as maintenance-/service switch
Version as emergency stop installation Version as main switch |
Special features |
|
Rated operating voltage (Ue) at AC - max |
690 V
|
Rated operating power at AC-23, 400 V |
200 kW
|
Rated operational current |
630 A (690 V AC-22/23A, making and breaking capacity)
630 A (415 V AC-22/23A, making and breaking capacity) |
Rated permanent current at AC-21, 400 V |
0 A
|
Rated conditional short-circuit current with back-up fuse |
PN3(N3)-400…630: 630 AgGgL
80 kA at 690 V 100 kA at 400/415 V |
Rated conditional short-circuit current with downstream fuse |
100 kA at 400/415 V
PN3(N3)-400…630: 630 AgGgL 80 kA at 690 V |
Rated short-time withstand current (Icw) |
12 kA
|
Rated short-time withstand current (t = 0.3 s) |
12 kA
|
Rated short-time withstand current (t = 1 s) |
12 kA
|
Amperage Rating |
400 A
|
Rated operating frequency |
50 Hz
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
25 kA
|
Rated operating power at AC-3, 400 V |
0 kW
|
Rated operating power at AC-23, 400 V |
200 kW
|
Switching power at 400 V |
0 kW
|
Short-circuit protective device fuses - max |
630 A gL
|
Electrical connection type of main circuit |
Frame clamp
|
Isolation |
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts) |
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
3000 operations at 400 V AC-3
5000 operations at 415 V AC-1 2000 operations at 690 V AC-3 5000 operations at 400 V AC-1 3000 operations at 415 V AC-3 3000 operations at 690 V AC-1 |
Direction of incoming supply |
As required
|
Voltage rating |
690 V - 690 V
|
Rated insulation voltage (Ui) |
1000 V
|
Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
Rated operational current |
630 A (690 V AC-22/23A, making and breaking capacity)
630 A (415 V AC-22/23A, making and breaking capacity) |
Rated permanent current at AC-21, 400 V |
0 A
|
Rated permanent current at AC-21, 400 V |
0 A
|
Rated conditional short-circuit current with back-up fuse |
PN3(N3)-400…630: 630 AgGgL
80 kA at 690 V 100 kA at 400/415 V |
Rated conditional short-circuit current (Iq) |
0 kA
|
Rated conditional short-circuit current with downstream fuse |
100 kA at 400/415 V
PN3(N3)-400…630: 630 AgGgL 80 kA at 690 V |
Rated short-time withstand current (Icw) |
12 kA
|
Rated short-time withstand current (t = 0.3 s) |
12 kA
|
Rated short-time withstand current (t = 1 s) |
12 kA
|
Amperage Rating |
400 A
|
Rated operating frequency |
50 Hz
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
25 kA
|
Rated operating power at AC-3, 400 V |
0 kW
|
Rated operating power at AC-23, 400 V |
200 kW
|
Switching power at 400 V |
0 kW
|
Short-circuit protective device fuses - max |
630 A gL
|
Electrical connection type of main circuit |
Frame clamp
|
Isolation |
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts) |
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
3000 operations at 400 V AC-3
5000 operations at 415 V AC-1 2000 operations at 690 V AC-3 5000 operations at 400 V AC-1 3000 operations at 415 V AC-3 3000 operations at 690 V AC-1 |
Direction of incoming supply |
As required
|
Mounting Method |
Built-in device fixed built-in technique
Intermediate mounting Ground mounting Distribution board installation Fixed |
Degree of protection |
IP20 (basic protection type, in the area of the HMI devices)
Other |
Degree of protection (IP), front side |
IP40 (with insulating surround)
IP20 IP66 (with door coupling rotary handle) |
Degree of protection (terminations) |
IP10 (tunnel terminal)
IP00 (terminations, phase isolator and band terminal) |
Protection against direct contact |
Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
|
Shock resistance |
20 g (half-sinusoidal shock 20 ms)
|
Number of auxiliary contacts (change-over contacts) |
0
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Number of switches |
1
|
Handle color |
Black
|
Switch positions |
I, 0
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Lifespan, mechanical |
15000 operations
|