Bilden är representativ
Download
Eaton Moeller series NZM Undervoltage release, 208-240VAC, +2early N/O, for NZM1, L
Product Name |
Eaton Moeller series NZM Undervoltage release
|
Catalog Number |
259565
|
EAN |
4015082595654
|
Product Length/Depth |
37 mm
|
Product Height |
66 mm
|
Product Width |
32 mm
|
Product Weight |
0.056 kg
|
Compliances |
IEC
UL/CSA RoHS conform |
Certifications |
CSA-C22.2 No. 5-09
CSA (Class No. 1437-01) UL489 IEC60947 UL listed CSA (File No. 22086) UL (Category Control Number DIHS) UL (File No. E140305) CSA certified CE marking |
Model Code |
NZM1-XUHIVL208-240AC
|
Type |
Accessory
Undervoltage release
Undervoltage release with early-make auxiliary contact
|
Special features |
Undervoltage release with 2 early-make auxiliary contacts, e.g., for early-make connection of undervoltage release in main switch applications, as well as for interlock and load shedding circuits.
For use with emergency-stop devices in connection with an emergency-stop button.
When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on.
Early make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms
Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.
|
Frame |
NZM1
|
Fitted with: |
Two early-make auxiliary contacts
|
Suitable for |
Off-load switch
|
Used with |
NZM1(-4), N(S)1(-4)
|
Rated control supply voltage |
208 - 240 V 50/60 Hz
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
208 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
208 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Voltage tolerance - min |
0.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
0.8 W (sealing DC)
1.5 VA (sealing AC) |
Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
Reaction time |
19 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Voltage type |
AC
|
Rated control voltage (relay contacts) |
240 V AC
208 V AC |
Rated control supply voltage |
208 - 240 V 50/60 Hz
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
208 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
208 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Voltage tolerance - min |
0.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
0.8 W (sealing DC)
1.5 VA (sealing AC) |
Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
Reaction time |
19 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
2
|
Connection type |
With 3 m connection cable instead of screw termination
|