Bilden är representativ
Download
Eaton Moeller series NZM Undervoltage release, 600VAC, for NZM4
Product Name |
Eaton Moeller series NZM Undervoltage release
|
Catalog Number |
266196
|
EAN |
4015082661960
|
Product Length/Depth |
107 mm
|
Product Height |
51 mm
|
Product Width |
64 mm
|
Product Weight |
0.218 kg
|
Compliances |
UL/CSA
IEC RoHS conform |
Certifications |
CSA (File No. 22086)
UL listed CSA-C22.2 No. 5-09 UL489 CSA certified UL (Category Control Number DIHS) CSA (Class No. 1437-01) IEC60947 UL (File No. E140305) CE marking |
Model Code |
NZM4-XU600AC
|
Type |
Accessory
Undervoltage release
|
Special features |
Non-delayed disconnection of NZM circuit-breaker or N switch-disconnector when the control voltage sinks below 35 – 70% US.
For use with emergency-stop devices in connection with an emergency-stop button.
When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on.
Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.
|
Frame |
NZM4
|
Suitable for |
Off-load switch
|
Used with |
NZM4(-4), N(S)4(-4)
|
Rated control supply voltage |
600 V 50/60 Hz
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
600 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
600 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
600 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
600 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Voltage tolerance - min |
.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
2.5 W (sealing DC)
3.6 VA (Sealing AC) |
Pick-up power consumption at AC (undervoltage release) |
3.6 VA
|
Pick-up power consumption at DC (undervoltage release) |
2.5 W
|
Reaction time |
23 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Voltage type |
AC
|
Rated control voltage (relay contacts) |
600 V AC
|
Rated control supply voltage |
600 V 50/60 Hz
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
600 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
600 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
600 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
600 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Voltage tolerance - min |
.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
2.5 W (sealing DC)
3.6 VA (Sealing AC) |
Pick-up power consumption at AC (undervoltage release) |
3.6 VA
|
Pick-up power consumption at DC (undervoltage release) |
2.5 W
|
Reaction time |
23 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
0
|
Connection type |
With bolt connection
|