Modellkod: NZM4-XA-230AC-MNS

Eaton Moeller series NZM Shunt release, 230VAC, for mesh network, size 4

General specifications

Product Name
Eaton Moeller series NZM Shunt release
Catalog Number
274138
EAN
4015082741389
Product Length/Depth
107 mm
Product Height
51 mm
Product Width
64 mm
Product Weight
0.218 kg
Compliances
IEC
RoHS conform
Model Code
NZM4-XA-230AC-MNS

Tekniska data – elektriska

Type
  • Accessory
  • Shunt release
Special features
  • Shunt release for mesh network circuit-breakers in conjunction with NZM-XZM capacitor unit
  • Only for short-time operation with a maximum on-time = 1 s
  • Operating range 10 - 110 % Us
  • not UL/CSA approved
  • Rated control voltage 230 V AC
  • Cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
  • Intermittent operation guaranteed by series connection of an M22-(C)K10 make contact.
Frame
NZM4
Suitable for
Off-load switch
Used with
NZM4(-4), N(S)4(-4)

Tekniska data – elektriska

Rated control supply voltage
230 V AC
Rated control supply voltage (Us) at AC, 50 Hz - min
230 V
Rated control supply voltage (Us) at AC, 50 Hz - max
230 V
Rated control supply voltage (Us) at AC, 60 Hz - min
230 V
Rated control supply voltage (Us) at AC, 60 Hz - max
230 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Current consumption - max
1 A
Frequency rating
50 Hz / 60 Hz (shunt release)
Reaction time
22 ms
Minimum command time - min
10 ms
Minimum command time - max
15 ms
Electric connection type
Screw connection

Tekniska data – kommunikation

Voltage type
AC
Voltage rating at AC (x Us) - min
0.1
Voltage rating at AC (x Us) - max
1.1
Rated control voltage (relay contacts)
230 V AC
Rated control supply voltage
230 V AC
Rated control supply voltage (Us) at AC, 50 Hz - min
230 V
Rated control supply voltage (Us) at AC, 50 Hz - max
230 V
Rated control supply voltage (Us) at AC, 60 Hz - min
230 V
Rated control supply voltage (Us) at AC, 60 Hz - max
230 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Current consumption - max
1 A
Frequency rating
50 Hz / 60 Hz (shunt release)
Reaction time
22 ms
Minimum command time - min
10 ms
Minimum command time - max
15 ms
Electric connection type
Screw connection

Tekniska data – mekaniska

Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
0