Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 1250A 1000V, AE1250-S1
Product Name |
Eaton Moeller series NZM molded case circuit breaker electronic
|
Catalog Number |
290373
|
EL Number |
3186575
|
EAN |
4015082903732
|
Product Length/Depth |
401 mm
|
Product Height |
207 mm
|
Product Width |
210 mm
|
Product Weight |
19 kg
|
Compliances |
RoHS conform
|
Certifications |
IEC
|
Model Code |
NZMH4-AE1250-S1
|
Type |
Circuit breaker
|
Circuit breaker frame type |
NZM4
|
Number of poles |
Three-pole
|
Release system |
Electronic release
|
Features |
Motor drive optional
Protection unit |
Special features |
|
Rated short-time withstand current (t = 0.3 s) |
19.2 kA
|
Rated short-time withstand current (t = 1 s) |
19.2 kA
|
Amperage Rating |
1250 A
|
Instantaneous current setting (Ii) - min |
2500 A
|
Instantaneous current setting (Ii) - max |
15000 A
|
Overload current setting (Ir) - min |
630 A
|
Overload current setting (Ir) - max |
1250 A
|
Short delay current setting (Isd) - min |
0 A
|
Short delay current setting (Isd) - max |
0 A
|
Short-circuit release non-delayed setting - min |
2500 A
|
Short-circuit release non-delayed setting - max |
15000 A
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
63 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
50 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
50 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
50 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
37 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 1000 V, 50/60 Hz |
15 kA
|
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
275 kA
|
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
187 kA
|
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
187 kA
|
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
143 kA
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
100 kA
|
Rated short-circuit making capacity Icm at 1000 V, 50/60 Hz |
40 kA
|
Electrical connection type of main circuit |
Screw connection
|
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Utilization category |
A
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
500 operations at 1000 V AC-1
|
Voltage rating |
1000 V - 1000 V
|
Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
Rated short-time withstand current (t = 0.3 s) |
19.2 kA
|
Rated short-time withstand current (t = 1 s) |
19.2 kA
|
Amperage Rating |
1250 A
|
Instantaneous current setting (Ii) - min |
2500 A
|
Instantaneous current setting (Ii) - max |
15000 A
|
Overload current setting (Ir) - min |
630 A
|
Overload current setting (Ir) - max |
1250 A
|
Short delay current setting (Isd) - min |
0 A
|
Short delay current setting (Isd) - max |
0 A
|
Short-circuit release non-delayed setting - min |
2500 A
|
Short-circuit release non-delayed setting - max |
15000 A
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
63 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
50 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
50 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
50 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
37 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 1000 V, 50/60 Hz |
15 kA
|
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
275 kA
|
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
187 kA
|
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
187 kA
|
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
143 kA
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
100 kA
|
Rated short-circuit making capacity Icm at 1000 V, 50/60 Hz |
40 kA
|
Electrical connection type of main circuit |
Screw connection
|
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Utilization category |
A
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
500 operations at 1000 V AC-1
|
Mounting Method |
Built-in device fixed built-in technique
Fixed |
Degree of protection |
IP20
|
Number of auxiliary contacts (change-over contacts) |
0
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Position of connection for main current circuit |
Front side
|
Lifespan, mechanical |
10000 operations
|