Ladda ner dokument () av 20

292343
Modellkod: NZM2-4-XFI30

Eaton Moeller series NZM Earth-fault release, 30mA, 4p

General specifications

Product Name
Eaton Moeller series NZM Earth leakage relay
Catalog Number
292343
EAN
4015082923433
Product Length/Depth
132 mm
Product Height
103 mm
Product Width
140 mm
Product Weight
2.504 kg
Compliances
IEC
RoHS conform
Certifications
IEC/EN 60947-2
IEC/EN 60947-2 annex B
Model Code
NZM2-4-XFI30

Tekniska data – elektriska

Application
In three- and single-phase systems
Type
Accessory Earth-fault releases
Number of poles
Four-pole
Special features
Earth-fault release to IEC/EN 60947-2 Not UL/CSA approved Suitable for use in three- and single-phase systems Pulse-current sensitive according to core-balance principle For 4 pole NZM2-4 circuit-breakers and N2-4 switch-disconnectors Supply voltage-dependent Ue = 280 – 690 V 50 Hz
Frame
96 mm
NZM2
Used with
NZM2-4
Four-pole
N2-4

Tekniska data – elektriska

Rated control supply voltage (Us) at AC, 50 Hz - min
280 V
Rated control supply voltage (Us) at AC, 50 Hz - max
690 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Current rating - min
15 A
Current rating - max
250 A
Rated fault current - min
0.03 A
Rated fault current - max
0.03 A
Fault current detection range
50 Hz
Frequency rating
50 Hz
Power on-delay time - min
30 ms
Power on-delay time - max
30 ms

Tekniska data – kommunikation

Sensitivity type
Pulse-current sensitive as per core-balance principle (type A)
Voltage rating
280 - 690 V AC (independent of mains voltage)
Rated operating voltage (Ue) - max
690 V
Rated control supply voltage (Us) at AC, 50 Hz - min
280 V
Rated control supply voltage (Us) at AC, 50 Hz - max
690 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Current rating - min
15 A
Current rating - max
250 A
Rated fault current - min
0.03 A
Rated fault current - max
0.03 A
Fault current detection range
50 Hz
Frequency rating
50 Hz
Power on-delay time - min
30 ms
Power on-delay time - max
30 ms

Tekniska data – mekaniska

Mounting Method
Bottom
Mounting position
Vertical and 90° in all directions
Degree of protection
IP20 (operating component area)
Shock resistance
20 g (half-sinusoidal shock 20 ms)
Lifespan, mechanical
≧ 2000 operations

Exportera produktspecifikationer