Ladda ner dokument () av 20

269192
Modellkod: NZMH2-AF35-NA

Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 35A, H, frame 2, AF35-NA

General specifications

Product Name
Eaton Moeller series NZM molded case circuit breaker thermo-magnetic
Catalog Number
269192
EAN
4015082691929
Product Length/Depth
149 mm
Product Height
195 mm
Product Width
105 mm
Product Weight
2.42 kg
Compliances
RoHS conform
Certifications
UL (File No. E31593)
CSA certified
UL listed
UL/CSA
CSA (Class No. 1432-01)
IEC 60947-2
IEC/EN 60947
IEC
UL 489
Specially designed for North America
CE marking
UL (Category Control Number DIVQ)
CSA (File No. 22086)
CSA-C22.2 No. 5-09
Model Code
NZMH2-AF35-NA

Tekniska data – elektriska

Application
  • Branch circuits, feeder circuits
  • Use in unearthed supply systems at 690 V
Type
Circuit breaker
Circuit breaker frame type
NZM2
Number of poles
Three-pole
Release system
Thermomagnetic release
Features
Protection unit
Motor drive optional
Special features
  • Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn)
  • Rated current = rated uninterrupted current: 35 A
  • Switches conform to UL/CSA as well as the IEC regulations. IEC switching performance values are contained on the rating plate.
  • Fixed overload releases Ir

Tekniska data – elektriska

Rated operational current
300 A (415 V AC-1, making and breaking capacity)
300 A (380/400 V AC-1, making and breaking capacity)
35 A (690 V AC -1, making and breaking capacity)
35 A (660-690 V AC-3, making and breaking capacity)
Rated short-time withstand current (t = 0.3 s)
1.9 kA
Rated short-time withstand current (t = 1 s)
1.9 kA
Amperage Rating
35 A
Instantaneous current setting (Ii) - min
8 A
Instantaneous current setting (Ii) - max
10 A
Overload current setting (Ir) - min
35 A
Overload current setting (Ir) - max
35 A
Short-circuit release non-delayed setting - min
280 A
Short-circuit release non-delayed setting - max
350 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz
150 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
150 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz
130 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz
37.5 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz
5 kA
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz
330 kA
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz
330 kA
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz
286 kA
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz
105 kA
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
40 kA
Short-circuit total breaktime
< 10 ms
Low-voltage HBC fuse - max
355 A gG/gL
Electrical connection type of main circuit
Screw connection
Isolation
500 V AC (between auxiliary contacts and main contacts)
300 V AC (between the auxiliary contacts)
Number of operations per hour - max
120
Handle type
Rocker lever
Utilization category
A (IEC/EN 60947-2)
Overvoltage category
III
Pollution degree
3
Lifespan, electrical
10000 operations at 400 V AC-1
5000 operations at 690 V AC-3
6500 operations at 415 V AC-3
7500 operations at 690 V AC-1
6500 operations at 400 V AC-3
Direction of incoming supply
As required

Tekniska data – kommunikation

Voltage rating
690 V - 690 V
Rated operating voltage Ue (UL) - max
600Y/347 V, 480 V
Rated impulse withstand voltage (Uimp) at auxiliary contacts
6000 V
Rated impulse withstand voltage (Uimp) at main contacts
8000 V
Rated operational current
300 A (415 V AC-1, making and breaking capacity)
300 A (380/400 V AC-1, making and breaking capacity)
35 A (690 V AC -1, making and breaking capacity)
35 A (660-690 V AC-3, making and breaking capacity)
Rated short-time withstand current (t = 0.3 s)
1.9 kA
Rated short-time withstand current (t = 1 s)
1.9 kA
Amperage Rating
35 A
Instantaneous current setting (Ii) - min
8 A
Instantaneous current setting (Ii) - max
10 A
Overload current setting (Ir) - min
35 A
Overload current setting (Ir) - max
35 A
Short-circuit release non-delayed setting - min
280 A
Short-circuit release non-delayed setting - max
350 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz
150 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
150 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz
130 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz
37.5 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz
5 kA
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz
330 kA
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz
330 kA
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz
286 kA
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz
105 kA
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
40 kA
Short-circuit total breaktime
< 10 ms
Low-voltage HBC fuse - max
355 A gG/gL
Electrical connection type of main circuit
Screw connection
Isolation
500 V AC (between auxiliary contacts and main contacts)
300 V AC (between the auxiliary contacts)
Number of operations per hour - max
120
Handle type
Rocker lever
Utilization category
A (IEC/EN 60947-2)
Overvoltage category
III
Pollution degree
3
Lifespan, electrical
10000 operations at 400 V AC-1
5000 operations at 690 V AC-3
6500 operations at 415 V AC-3
7500 operations at 690 V AC-1
6500 operations at 400 V AC-3
Direction of incoming supply
As required

Tekniska data – mekaniska

Mounting Method
Fixed
DIN rail (top hat rail) mounting optional
Built-in device fixed built-in technique
Degree of protection
IP20
IP20 (basic degree of protection, in the operating controls area)
Degree of protection (IP), front side
IP40 (with insulating surround)
IP66 (with door coupling rotary handle)
Degree of protection (terminations)
IP00 (terminations, phase isolator and strip terminal)
IP10 (tunnel terminal)
Protection against direct contact
Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Shock resistance
20 g (half-sinusoidal shock 20 ms)
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Position of connection for main current circuit
Front side
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Lifespan, mechanical
20000 operations

Exportera produktspecifikationer

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Autentisera produkten

Ange ditt serienummer med 16–17 siffror
Det angivna serienumret får inte innehålla specialtecken. Det angivna serienumret är inte korrekt. Det ska bestå av 16 eller 17 siffror. Det angivna serienumret hittades inte. Försök igen eller rapportera ett problem för ytterligare hjälp. Det angivna serienumret matchar inte produkten. Kontrollera produktens serienummer och försök igen. Klicka här för att navigera till produktsidan för serienumret du angett Eaton känner till att serienumret är misstänkt, försök igen eller rapportera ett problem för ytterligare hjälp.
Serienummer
Återställ Eaton känner till att serienumret är misstänkt, försök igen eller rapportera ett problem för ytterligare hjälp. Serienumret känns inte igen av Eaton och är ogiltigt. Använd detta formulär för att rapportera ett problem för ytterligare hjälp.
Ange den 6-siffriga autentiseringskoden
Den angivna produkten är misstänkt! Försök igen eller rapportera ett problem för ytterligare hjälp. Den angivna autentiseringskoden matchar inte våra register för detta serienummer. Försök igen eller rapportera ett problem för ytterligare hjälp. Ogiltig autentiseringskod. Längden måste vara 6 tecken rapportera ett problem för ytterligare hjälp. Autentiseringskod krävs rapportera ett problem för ytterligare hjälp.
Slutföra Captcha-utmaningen före autentiseringen.
Kontakta oss rapportera problem
x
Rapportera ett problem
Ange ditt fullständiga namn.
x
Tack, ditt ärende har skickats in. Vårt produktteam ska kontakta dig snart!
Observera: Om fil(er) saknas från .zip nedladdningen stöds filtypen inte av massnedladdning.