Reset
NZMN4-PMX1400-AVE. NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 1400A, 3p, Screw terminal, withdrawable unit
| Product Name |
Eaton Moeller series NZM molded case circuit breaker electronic
|
| Catalog Number |
189689
|
| EAN |
4015081876365
|
| Product Length/Depth |
501 mm
|
| Product Height |
280 mm
|
| Product Width |
260 mm
|
| Product Weight |
29 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC
IEC/EN 60947 |
| Model Code |
NZMN4-PMX1400-AVE
|
| Voltage rating |
690 V - 690 V
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
| Rated short-time withstand current (t = 0.3 s) |
19.2 kA
|
| Rated short-time withstand current (t = 1 s) |
19.2 kA
|
| Amperage Rating |
1400 A
|
| Instantaneous current setting (Ii) - min |
2 A
|
| Instantaneous current setting (Ii) - max |
14 A
|
| Overload current setting (Ir) - min |
560 A
|
| Overload current setting (Ir) - max |
1400 A
|
| Short-circuit release non-delayed setting - min |
2800 A
|
| Short-circuit release non-delayed setting - max |
19600 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
37 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
26 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
26 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
19 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
15 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
74 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
53 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
40 kA
|
| Rated operating power at AC-3, 230 V |
450 kW
|
| Rated operating power at AC-3, 400 V |
800 kW
|
| Short-circuit total breaktime |
< 25 ms (≦ 415 V); < 35 ms (> 415 V)
|
| Electrical connection type of main circuit |
Other
|
| Isolation |
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts) |
| Number of operations per hour - max |
60
|
| Handle type |
Rocker lever
|
| Utilization category |
B (IEC/EN 60947-2)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
3000 operations at 415 V AC-1
1000 operations at 690 V AC-3 2000 operations at 400 V AC-3 2000 operations at 690 V AC-1 3000 operations at 400 V AC-1 2000 operations at 415 V AC-3 |
| Direction of incoming supply |
As required
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
| Rated short-time withstand current (t = 0.3 s) |
19.2 kA
|
| Rated short-time withstand current (t = 1 s) |
19.2 kA
|
| Amperage Rating |
1400 A
|
| Instantaneous current setting (Ii) - min |
2 A
|
| Instantaneous current setting (Ii) - max |
14 A
|
| Overload current setting (Ir) - min |
560 A
|
| Overload current setting (Ir) - max |
1400 A
|
| Short-circuit release non-delayed setting - min |
2800 A
|
| Short-circuit release non-delayed setting - max |
19600 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
37 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
26 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
26 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
19 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
15 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
74 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
53 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
40 kA
|
| Rated operating power at AC-3, 230 V |
450 kW
|
| Rated operating power at AC-3, 400 V |
800 kW
|
| Short-circuit total breaktime |
< 25 ms (≦ 415 V); < 35 ms (> 415 V)
|
| Electrical connection type of main circuit |
Other
|
| Isolation |
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts) |
| Number of operations per hour - max |
60
|
| Handle type |
Rocker lever
|
| Utilization category |
B (IEC/EN 60947-2)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
3000 operations at 415 V AC-1
1000 operations at 690 V AC-3 2000 operations at 400 V AC-3 2000 operations at 690 V AC-1 3000 operations at 400 V AC-1 2000 operations at 415 V AC-3 |
| Direction of incoming supply |
As required
|
| Mounting Method |
Built-in device slide-in technique (withdrawable)
Withdrawable |
| Degree of protection |
IP20 (basic degree of protection, in the operating controls area)
IP20 |
| Degree of protection (IP), front side |
IP40 (with insulating surround)
IP66 (with door coupling rotary handle) |
| Degree of protection (terminations) |
IP10 (tunnel terminal)
IP00 (terminations, phase isolator and strip terminal) |
| Protection against direct contact |
Finger and back-of-hand proof to VDE 0106 part 100
|
| Shock resistance |
15 g (half-sinusoidal shock 11 ms)
|
| Switch off technique |
Electronic
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Lifespan, mechanical |
10000 operations
|